Cooper Lighting M32T Indoor Furnishings User Manual


 
PHOTOMETRICS
P7-M42T-E7TC
Test No. H35091
Lamp: 42W PLT
Lumens: 3200
Cutoff: 50°
Spacing: 1.0
Efficiency: 44.8%
Unit LPW: 27.0
Unit Number: P7-M42T-E7T_
P7-M32T-E7T_
Candelas
Vertical CD
Angle
90 0
85 0
75 0
65 0
55 1
45 142
35 594
25 947
15 1313
5 1397
0 1279
Luminance
Degree cd/m
2
85
˚
0
75
˚
0
65
˚
0
55
˚
76
45
˚
8768
4'6"
5'6"
6'6"
8'0"
10'0"
12'0"
4'6"
5'6"
6'6"
8'0"
10'0"
12'0"
63
42
30
20
13
9
Cone of Light
Distance to Initial Nadir Beam
Illuminated Plane Footcandles Diameter
Notes and Formulas:
Luminance: To convert cd/m
2
to footlamberts, multiply by 0.2919
Cone of Light:
• Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
• Footcandle values are initial. Apply appropriate light loss factors where necessary.
See page 64-65 of catalog.
CU Notes/Formulas:
• maintained illuminance=lamp lumens x CU x light loss factors
room area
• total number of luminaires=total room area x maintained illuminance
lamp lumens x CU x light loss factors
• CU data based on 20% effective floor cavity reflectance.
80% 70% 50% 30% 0%
70 50 30 10 50 10 50 10 50 10 0
53 53 53 53 52 52 50 50 48 48 45
50 48 47 45 47 44 45 43 43 42 40
47 45 43 41 44 40 42 39 41 39 37
45 42 39 37 41 37 40 36 39 36 35
43 39 36 34 38 34 37 34 37 33 32
40 36 34 32 36 31 35 31 34 31 30]
38 34 31 29 34 29 33 29 32 29 28
36 32 29 27 32 27 31 27 31 27 26
34 30 27 25 30 25 29 25 29 25 24
33 28 25 24 28 23 27 23 27 23 23
31 26 24 22 26 22 26 22 26 22 21
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
Coefficient of UtilizationZonal Lumen Summary
Zone Lumens %Lamp %Luminaire
0-30 933 29.2 65.1
0-40 1299 40.6 90.6
0-60 1433 44.8 100.0
0-90 1433 44.8 100.0
90-180 0 0.0 0.0
0-180 1433 44.8 100.0
Distribution
P7-M32T-E7TC
Test No. H35094
Lamp: 32W PLT
Lumens: 2400
Cutoff: 50°
Spacing: 0.9
Efficiency: 43.4%
Unit LPW: 28.9
Candelas
Vertical CD
Angle
90 0
85 0
75 0
65 0
55 1
45 75
35 371
25 701
15 1083
5 1159
0 1083
Luminance
Degree cd/m
2
85
˚
0
75
˚
0
65
˚
0
55
˚
76
45
˚
4631
4'6"
5'6"
6'6"
8'0"
10'0"
12'0"
4'0"
5'0"
6'0"
7'6"
9'0"
11'0"
54
36
26
17
11
8
Cone of Light
Distance to Initial Nadir Beam
Illuminated Plane Footcandles Diameter
80% 70% 50% 30% 0%
70 50 30 10 50 10 50 10 50 10 0
52 52 52 52 50 50 48 48 46 46 43
48 46 45 43 45 43 44 41 42 40 38
46 43 41 39 42 39 41 38 40 37 36
44 40 38 36 40 36 39 35 38 35 33
41 38 35 33 37 33 36 33 36 32 31
39 35 33 31 35 31 34 30 34 30 29
37 33 31 29 33 29 32 28 32 28 27
35 31 29 27 31 27 30 26 30 26 26
34 29 27 25 29 25 29 25 28 25 24
32 28 25 23 27 23 27 23 27 23 22
30 26 24 22 26 22 26 22 25 22 21
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
Coefficient of UtilizationZonal Lumen Summary
Zone Lumens %Lamp %Luminaire
0-30 733 30.5 70.4
0-40 964 40.2 92.6
0-60 1041 43.4 100.0
0-90 1041 43.4 100.0
90-180 0 0.0 0.0
0-180 1041 43.4 100.0
Distribution
Note: Specifications and Dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801
ADI030703