PHOTOMETRICS
ORDERING INFORMATION
SHIPPING INFORMATION
I8
Candela
Angle Along II 45° Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
3547 3547 3547
3526 3528 3516
3477 3393 3233
3394 3104 2822
3281 2757 2455
3138 2426 2159
2967 2149 1921
2771 1873 1698
2548 1640 1486
2305 1415 1317
2041 1196 1266
1759 1021 1196
1465 945 1097
1160 842 953
853 709 769
552 528 581
270 334 271
51 64 17
0 3 1
Coefficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Zonal Lumen Summary
Zone Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
0-180
I8-332-UNV-UPL
Electronic Ballast
F28T8-SP35 Lamps
2750 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 0.9 x
mounting height
Efficiency 96.2%
Test Report:
I8332UNVUPL.IES
LER = FL-94
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.54
2384 28.9 30.0
3656 44.3 46.1
5946 72.1 74.9
7451 90.3 93.9
7935 96.2 100.0
113 113 113 113 110110 110 110 104 104 104 98 98 98 93 93 93 90
104 99 95 92 100 97 93 90 91 88 86 87 84 82 82 80 79 76
95 87 81 75 91 85 79 74 80 75 71 76 72 69 73 69 66 64
86 77 69 63 84 75 68 62 71 65 60 68 63 59 65 60 57 55
79 68 60 54 77 67 59 53 64 57 52 61 55 51 58 53 49 47
73 61 53 47 71 60 52 46 57 51 45 55 49 44 52 47 43 41
68 56 47 41 66 54 47 41 52 45 40 50 44 39 48 43 38 36
63 51 42 37 61 50 42 36 48 41 36 46 40 35 44 39 34 33
59 46 38 33 57 45 38 33 44 37 32 42 36 32 41 35 31 29
55 43 35 30 54 42 35 30 40 34 29 39 33 29 38 32 28 27
52 40 32 27 50 39 32 27 38 31 27 36 31 26 35 30 26 24
SAMPLE NUMBER: 8TI8-332-EB82/PLUS-UPL-U
NOTES:
(1)
Requires use of MC or MPC cord accessories, specify voltage for plugs.
(2)
Use with wide distribution optic only.
(3)
Voltage must be
specified when ordered with plugs, motion sensors or emergency ballasts.
(4)
ER8 and EB8 ballast systems suitable for operation in ambient
environments up to 122°F (50°C) in open uplight configurations.
(5)
Specify voltage.
(6)
For use with Top Connector Box options. See accessories.
(7)
TAP
option available with a maximum of two ballasts, including EM battery pack.
(8)
Not for use in gymnasiums or similar recreational facilities.
(9)
Dimming
ballast must be specified at time of order.
No. of Lamps
3=3 Lamps
Lamp Type
32=32W T8 (4') Lamps
Series
I8=T8 Industrial
Length
Blank=4' Length
8T=8' Length
Voltage
(3)
UNV=Universal
120/277 Voltage
UNC=Universal
347/480 Voltage
120V=120 Volt
277V=277 Volt
347V=347 Volt
480V=480 Volt
Shielding Options
Blank=Open
TBW=Thin White Baffle
FL=Frosted Acrylic Lens & Frame
(2)
CL=Clear Acrylic Lens & Frame
ASY= Asymmetric DirectionalLouver
(2)
WG=Heavy Duty Wireguard
Distribution Optic
Blank=Medium (Specular Aluminum)
G=Wide (High Reflectance White)
Mounting Arrangement
Blank=Stand Alone
R=Continuous Row Mount
Options
I8 Lamps Installed
L8830=T8 Lamp, 85CRI 3000K
L8835=T8 Lamp, 85CRI 3500K
L8841=T8 Lamp, 85CRI 4100K
L8850=T8 Lamp, 85CRI 5000K
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency Installed
(3)
Options
NUA=No Uplight Apertures In Housing
(Cannot be combined w/UPL)
UPL=Uplight Apertures
PI/CPI=Plug-In (1, 2 or 3)
(see ordering information)
TILW=Tandem Inline Wiring
MWS=Modular Wiring System
MS=Aisle Coverage Motion Sensor
(5)
MSO=360° Coverage Motion Sensor
(5)
C3=3' Power Cord
C6=6' Power Cord
MP=Modular Power Receptacle
(1) (3)
PC3-=3' Power Cord & Plug (Specify Voltage)
TAP=Top Access Plate
(7)
TCBP=Top Connector Box Plate
(6)
Packaging
U=Unit Pack
PAL=Palletized
Out of Carton
PALC=Palletized
In Carton
Ballast Type
T8 Systems
EB8 =T8 Electronic Instant Start.
(4)
Total Harmonic Distortion < 10%
EB8 /PLUS= T8 Electronic Instant Start.
(4)
High Ballast Factor >1.15.
Total Harmonic Distortion < 10%
ER8 =T8 Electronic Program Rapid Start.
(4)
Total Harmonic Distortion < 10%
ER8 /PLUS=T8 Electronic Program Rapid Start.
High Ballast Factor >1.15.
Total Harmonic Distortion < 10%
DIM=Consult Factory
(9)
No. of Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
Accessories (order separately)
TCB=Top Connector Box
RH-1=Retrofit Hanger
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook w/ Safety Screw
PC3-=3' Power Cord & Plug (Specify Voltage)
PC6-=6' Power Cord & Plug (Specify Voltage)
AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-
Hooks
(8)
GRIPPLE TOGGLE-=Single Toggle, #2 Cable (Specify 10' or
30')
GRIPPLE LOOP-=Loop Hanger, #2 Cable (Specify 10' or
30')
MC6=6' Modular Power Cord
MPC6=6' Modular Power Cord & Plug (Specify
Voltage)
MMS-CPD1200H=Aisle Motion Sensor, Box, Modular
Power Receptacle (120/277V)
MMS-CPD500H=360° Motion Sensor, Box, Modular
Power Receptacle (120/277V)
Door Frames (for Field Installation)
I8-FRM/LENS PK=Frosted Acrylic Lens & Frame (I8)
I8-FRM/CL PK=Clear Acrylic Lens & Frame (I8)
WG/I8-4FT-B=Heavy Duty Wireguard (I8)
BAFFLE 4FT I8 (White) 11571919=Thin White Blade
Baffle (I8)
BAFFLE 4FT I8=Thin White Blade Baffle (I8)
90801PPK=Asymmetrical Directional Louver
No. of
Ballast
1, 2 or 3
I8-332-UNV-UPL 15 lbs.
8TI8-332-UN
V-UPL 30 lbs.
Catalog No. Wt.