Cooper Lighting HVL Indoor Furnishings User Manual


 
PHOTOMETRICS
HVLSINGLE 8” LINEAR
NOTES: See option/accessories or technical sections for additional detailed product data. Specifications and Dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 Fax 770.486.4801 ADC050453
0
||
HVL8-117-UNV-C-EB81-S
Electronic Ballast
(1) F17T8/TL841 Lamp
1300 Lumens
Spacing criterion:
(II) 1.1 x mounting
height, () 1.3 x
mounting height
Efficiency 68.9%
Test Report
242p108
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $3.04
Candela
Angle Along II 45° Across
0 259 259 259
10 253 251 252
20 229 233 238
30 187 213 227
40 140 190 214
50 101 163 200
60 67 136 179
70 35 103 150
80 7 80 150
90 0 35 82
100 0 13 37
110 0 6 16
120 0 3 7
130 0 1 3
140 0 0 2
150 1 0 0
160 1 1 0
170 1 1 1
180 1 1 1
Typical VCP Percentages
Height Along Height Across
Room Size (Ft.) 8.5’ 10.0’ 8.5’ 10.0’
20 x 20 69 77 48 59
30 x 30 61 66 36 45
30 x 60 62 66 25 29
60 x 30 54 60 42 50
60 x 60 53 56 28 32
Zonal Lumen Summary
Zone Lumens %Lamp %Fixture
0-30 196 15.0 21.8
0-40 319 24.6 35.7
0-60 581 44.7 64.8
0-90 850 65.4 94.9
90-180 46 3.5 5.1
0-180 896 68.9 100.0
Coefficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 81 81 81 81 79 79 79 79 75 75 75 71 71 71 67 67 67 65
1 72 68 64 61 70 66 63 60 62 60 57 59 57 55 56 54 52 51
2 65 58 53 48 63 57 52 47 54 49 46 51 47 44 48 45 43 41
3 59 51 44 39 57 49 44 39 47 42 38 44 40 37 42 38 35 34
4 54 45 38 33 52 43 37 33 41 36 32 39 35 31 37 33 30 28
5 49 40 33 28 47 39 33 28 37 31 27 35 30 27 33 29 26 24
6 45 36 29 24 44 35 29 24 33 28 24 32 27 23 30 26 23 21
7 42 32 26 21 41 32 26 21 30 25 21 29 24 20 28 23 20 19
8 39 29 23 19 38 29 23 19 28 22 19 26 22 18 25 21 18 16
9 37 27 21 17 35 26 21 17 25 20 17 24 20 16 23 19 16 15
10 34 25 19 15 33 24 19 15 23 18 15 23 18 15 22 18 15 13
0
||
HVL8-217-UNV-O-EB81-S
Electronic Ballast
(2) F17T8/TL841 Lamp
1300 Lumens ea.
Spacing criterion:
(II) 1.3 x mounting
height, () 1.3 x
mounting height
Efficiency 49.6%
Test Report
242p105
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $3.04
Candela
Angle Along II 45° Across
0 405 405 405
10 399 399 399
20 378 379 381
30 344 347 351
40 298 304 310
50 242 251 260
60 179 190 204
70 109 128 148
80 40 73 97
90 0 34 56
100 0 12 28
110 0 4 12
120 0 3 6
130 0 2 4
140 1 1 2
150 1 1 2
160 1 1 1
170 2 2 2
180 2 2 2
Typical VCP Percentages
Height Along Height Across
Room Size (Ft.) 8.5’ 10.0’ 8.5’ 10.0’
20 x 20 53 61 48 57
30 x 30 47 51 41 46
30 x 60 43 46 33 37
60 x 30 49 52 45 49
60 x 60 43 45 36 38
Zonal Lumen Summary
Zone Lumens %Lamp %Fixture
0-30 317 12.2 24.6
0-40 522 20.1 40.4
0-60 935 35.9 72.4
0-90 1250 48.1 96.8
90-180 41 1.6 3.2
0-180 1291 49.6 100.0
Coefficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 59 59 59 59 57 57 57 57 54 54 54 52 52 52 49 49 49 48
1 53 50 48 46 51 49 47 45 47 45 43 44 43 42 42 41 40 39
2 48 44 40 37 46 43 39 36 40 38 35 39 36 34 37 35 33 32
3 44 38 34 30 42 37 33 30 35 32 29 34 31 29 32 30 28 27
4 40 34 29 26 39 33 29 25 31 28 25 30 27 24 29 26 24 23
5 37 30 25 22 35 29 25 22 28 24 21 27 24 21 26 23 21 20
6 34 27 22 19 33 26 22 19 25 22 19 24 21 18 23 20 18 17
7 31 24 20 17 30 24 20 17 23 19 16 22 19 16 21 18 16 15
8 29 22 18 15 28 22 18 15 21 17 15 20 17 15 20 17 14 13
9 27 20 16 13 26 20 16 13 19 16 13 19 15 13 18 15 13 12
10 25 19 15 12 25 18 15 12 18 14 12 17 14 12 17 14 12 11