Cooper Lighting GW Indoor Furnishings User Manual


 
Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
04/17/2007 10:38:16 AM
Specifications and Dimensions subject to change without notice.
ADC041424
PHOTOMETRICS
ORDERING INFORMATION
ORDERING MATRIX
12 " SQUARE
GC/GW
Candlepower Distribution
Test No. 766618
HPGC-150N-120V
Lamp=150W HPS
Lumens=16000
5
4
3
2
1
0
1
2
3
4
5
5 4 3 2 1 0 1 2 3 4 5
A B C D E F
Footcandle Table
Select mounting height and read across for footcandle values
of each isofootcandle line.
Mounting
Height Footcandle Values for
GC-2 Isofootcandle Lines
A B C D E F
6' 22.50 11.25 4.50 2.25 1.13 0.45
9' 10.00 5.00 2.00 1.00 0.50 0.20
12' 5.63 2.81 1.13 0.56 0.28 0.11
Notes:
For additional options, consult your Cooper Lighting Representative. Specifications and dimensions subject to change without notice.
Products also available in non-US voltages and 50Hz for international markets.
1. Supplied from factory with deep casting. 2. Not available with white lens. 3. Only available in HPF
.