Cooper Lighting FSR24 Indoor Furnishings User Manual


 
Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
03/29/2007 8:39:18 AM
Specifications and Dimensions subject to change without notice.
ADC041611
PHOTOMETRICS
ORDERING INFORMATION
FSR24
600
1200
1800
2400
3000
Candlepower Distribution
Zonal Lumen Summary
Zone Lumens %Lamp %Luminaire
0-30 2195 22.9 32.0
0-40 3713 38.7 54.2
0-60 5992 62.4 87.5
0-90 6852 71.4 100.0
90-180 0 0.0 0.0
0-180 6852 71.4 100.0
80% 70% 50% 30% 10% 0%
70 50 30 10 50 30 10 50 10 50 10 50 10 0
85 85 85 85 83 83 83 79 79 76 76 73 73 71
79 76 74 71 75 72 70 72 68 69 66 66 64 63
73 68 64 61 67 63 60 64 59 62 57 60 56 55
68 61 56 52 60 56 52 58 51 56 50 55 49 48
63 55 50 45 54 49 45 52 44 51 44 49 43 42
58 49 44 39 49 43 39 47 39 46 38 44 38 36
53 45 39 34 44 38 34 43 34 41 34 40 33 32
49 40 34 30 40 34 30 38 30 37 30 37 29 28
45 36 30 26 36 30 26 35 26 34 26 33 26 24
42 32 27 23 32 26 23 31 23 30 22 30 22 21
39 29 24 20 29 24 20 28 20 28 20 27 20 19
rc=Ceiling reflectance, rw=W all reflectance, RCR=Room cavity ratio
CU Data Based on 20% Effective Floor Cavity Reflectance.
Test No. 5933
FMR24-X-340
Lamp=(3) F40T12RS/
WW
Lumens=3200
Spacing Criteri
a
=1.
5 =1.3
Efficiency=71.4%
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Coefficient of Utilization
Candlepower
Deg.
0 2692 2692
5 2665 2654
15 2714 2627
25 2686 2443
35 2611 2143
45 2019 1512
55 1125 861
65 583 542
75 331 324
85 87 81
90 0 0
LNL= LED Night Light
(50,000 hrs.) provided
by Cooper
SAMPLE NUMBER: FSR-TG-X24-240-120-80/86-LE3-GLR