Cooper Lighting Entri Series Indoor Furnishings User Manual


 
INVUE WEBSITE
Visit invuelighting.com for the latest product information from INVUE Lighting Systems. With instant access to IES photometric files, PDF product specification sheets, new
product announcements, and other helpful specification tools, the INVUE Lighting website is an invaluable resource for getting information to customers-quickly.
APPLICATIONS DEPARTMENT
Let the application experts at Cooper Lighting design your next lighting layout. Aided by the latest computer simulation software and a comprehensive lighting background,
our Application Engineers can design, analyze, and provide statistical layouts for any lighting application. Whether the design criteria calls for Illuminance, Luminance, or
Small Target Visibility (STV) compliance, Cooper Lighting can provide the fixture layout and supporting documentation necessary to help secure your next project.
ORDERING INFORMATION
Sample Number: ENC-150-MH-120-EB-3S-BK-LG-L
Product Family
ENC=ENTRI
Round
Clean
ENV=ENTRI
Round
Reveals
ENT=ENTRI
Triangle
Reveals
Options (add as suffix)
F=Single Fuse (120, 277, or 347V)
Specify Voltage
FF=Double Fused (208V, 240V or 480V)
Specify Voltage
DSAB=Dual Fluorescent Switching Control Adapter Box
12
QAB=Quartz Restrike Adapter Box
EMAB=Quartz Restrike with Delay Adapter Box
(Also Strikes at Cold Start)
EM/SCAB=Quartz Emergency Separate Circuit Adapter Box
CF/EMAB=Emergency Battery Backup Adapter Box
13
PC=Button Type Photocontrol (Specify Voltage)
WG=Wire Guard
FRM=Frosted Main Flat Glass
FRS=Frosted Secondary Flat Glass
14
L=Lamp Included (Standard for all Quartz Halogen lamps)
Accessories (order separately/add
color suffix)
VA2001-XX=Thru-way Box
Lamp
Wattage
1
HID
39=39W
70=70W
100=100W
150=150W
Compact
Fluorescent
2
26=26W
32=32W
42=42W
52=(2)26W
3
57=57W
4
64=(2)32W
3
84=(2)42W
3
Quartz
Halogen
5
100=100W
150=150W
250=250W
Lamp Type
MH=Metal Halide
WS=WhiteSON HPS
6
CF=Compact
Fluorescent
7
HL=Quartz Halogen
Voltage
8
120=120V
208=208V
240=240V
277=277V
347=347V
DT=Dual-Tap
Wired 277V
9
MT=Multi-Tap
Wired 277V
9
TT=Triple-Tap
Wired 347V
9
Distribution
Up or Down
HID and
Quartz Halogen
3S=Type III
FT=Forward Throw
FX=Wall Grazing
Optic
TS=Tight Spot
Up/Down HID and
Quartz Halogen
3SG=Type III, 90%
Main/10%
Secondary Glow
3SP=Type III Main/
Pencil
Secondary
FTG=Forward Throw,
90% Main/
10% Secondary
Glow
FTP=Forward Throw
Main/ Pencil
Secondary
FXF=Wall Grazing
Optic,
50% Up/50%
Down
TSF=Tight Spot, 50%
Up/50% Down
Compact Fluorescent
CFM=100% Main, Up
or Downlighitng
CFG=90% Main/10%
Secondary Glow
Colors
(add as suffix/must specify)
11
BK=Black
AP=Grey
BZ=Bronze
WH=White
DP=Dark Platinum
GM=Graphite Metallic
NOTES: 1 All MH lamps are T6 envelope with G12 lamp base. White SON HPS lamp is T6 envelope with GX12 lamp base. 2 All 26/32/42/57W CF lamps feature
a 4-pin lamp base. Available in CFM and CFG distributions only. 3 Dual compact fluorescent lamps. 4 Nominal M.O.L lamp length of 57W CFL not to exceed 7".
5 All Halogen lamps are T4 envelope with mini-can screw base. 6 White SON HPS lamp available in 100W only. Requires electronic ballast. 120 through 277V
only. Requires use of VA2001 accessory Thru-way Box. 7 Compact Fluorescent ballasts contain internal fusing. No supplemental fusing is necessary. CF ballasts
are 120 through 277V. 8 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering
information. 9 Dual-tap is 120/277V wired 277V. Multi-tap is 120/208/240/277V wired 277V. Triple-tap is 120/277/347V wired 347V. 10 120 through 277V
only. Electronic ballast available with all CF lamps, and 39/70/100W MH lamps. Available with 150W MH lamp with use of VA2001 accessory Thru-way Box.
11 RAL and custom color matches available upon request. Consult your INVUE Lighting Systems Representative for more information. 12 Dual switching
requires dual 26, 32 or 42W CF lamps. Allows independent switching control of each lamp through use of two (2) electronic ballasts. Allows 50% power
reduction when dual ballasts are independently wired and controlled. 13 Battery backup provides 90 minutes of supplemental light at 60% of initial rated
lamp lumens. Must specify 26/32/42W Compact Fluorescent lamps. 14 Frosted secondary lens standard on 3SG, FTG, and CFG distributions.
22
ENTRI Series Architectural Wall Luminaire
DIMENSIONS [ENC | ENV | ENT]
ENC | ENV | ENT
Metal Halide 39, 70, 100, 150W
White Son HPS 100W
Compact Fluorescent 26, 32, 42, 57W
Dual Compact Fluorescent (2) 26, (2) 32, (2) 42W
Quartz Halogen 100, 150, 250W
WATTAGE TABLE
ENC | ENV | ENT
Net. Weight (lbs.) 17
Volume (cu. ft.) 1.64
NOTE: The above are approximate weights and volumes.
SHIPPING DATA
Optional Luminous
Faceplate Insert (add as suffix)
LG=Luminous Glass Insert
LGO=Luminous Glass Insert with
Warm Orange Gel
LGR=Luminous Glass Insert
with Red Gel
LGB=Luminous Glass Insert
with Bright Blue Gel
LGG=Luminous Glass Insert
with Deep Green Gel
Ballast
MB=Magnetic
(MH only)
EB=Electronic
10
X=None (for
Halogen Lamp)
GM
Graphite Metallic
WH
White
DP
Dark Platinum
BZ
Bronze
BK
Black
AP
Grey
STANDARD COLORS
7 3/4"
[196 mm]
15 25/32" [400 mm] 8 1/8" [206 mm]
7 3/4"
[196 mm]
15 25/32" [400 mm] 8 1/8" [206 mm]