Cooper Lighting E4DL Indoor Furnishings User Manual


 
IRiS • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
02/28/2008 11:34:24 AM
Specifications and Dimensions subject to change without notice.
ADI060741
Photometrics
P408ICAT MH4CFL42E E4DL E4DLCB
Downlight
45°
30°15°
60°
75°
90°
300
600
900
90º
D FC L W
4' 47 4.0' 4.9'
5' 30 5.0' 6.2'
6' 21 6.1' 7.4'
7' 15 7.1' 8.7'
8' 12 8.1' 9.9'
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
2
15
44
11 3
248
396
525
650
704
711
Zone Lumens
%
Lamp
%
Luminaire
0- 30 568 23.7 46.8
0- 40 856 35.7 70.5
0- 60 1162 48.4 95.7
0- 90 1214 50.6 100
90-180 0 0 0
0-180 1214 50.6 100
Spacing Criterion = 1, 1.3
Efficiency = 50.6%
Test No. 254P232
Platform = P4
Element = E4DLH
Lumens = 2400
Lamp = CF32TTT/E/841
Ceiling
Wall %
RCR
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal cavity method -- floor reflectance = 20%
0 60 60 60 60 59 59 59 59 56 56 56 54 54 54 52 52 52 51
1 57 55 53 52 55 54 52 51 52 51 50 50 49 48 48 47 47 46
2 53 50 47 45 52 49 47 45 47 45 44 46 44 43 44 43 42 41
3 49 45 42 40 48 45 42 39 43 41 39 42 40 38 41 39 37 37
4 46 41 38 35 45 41 37 35 40 37 35 38 36 34 37 35 34 33
5 43 38 34 31 42 37 34 31 36 33 31 35 33 31 35 32 30 30
6 40 35 31 28 39 34 31 28 33 30 28 33 30 28 32 30 28 27
7 38 32 28 26 37 32 28 26 31 28 26 30 27 25 30 27 25 24
8 35 30 26 24 35 29 26 23 29 26 23 28 25 23 28 25 23 22
9 33 28 24 22 33 27 24 22 27 24 21 26 23 21 26 23 21 20
10 31 26 22 20 31 25 22 20 25 22 20 25 22 20 24 22 20 19
Photometric Results Candlepower Distribution
Coefficients of Utilization
Cone of Light Zonal Lumens SummaryCandelas
Downlight
45°
30°15°
60°
75°
90°
160
320
480
90º
D FC L W
4' 28 4.0' 4.9'
5' 18 5.0' 6.1'
6' 12 6.0' 7.3'
7' 9 7.0' 8.6'
8' 7 8.0' 9.8'
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
1
8
24
61
140
239
338
427
442
438
Zone Lumens
%
Lamp
%
Luminaire
0- 30 339 18.8 47.6
0- 40 507 28.2 71.3
0- 60 682 37.9 95.9
0- 90 711 39.5 100
90-180 0 0 0
0-180 711 39.5 100
Spacing Criterion = 1, 1.2
Efficiency = 39.5%
Test No. 254P229
Platform = P4
Element = E4DLH
Lumens = 1800
Lamp = CF26TTT/E/830
Ceiling
Wall %
RCR
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal cavity method -- floor reflectance = 20%
0 47 47 47 47 46 46 46 46 44 44 44 42 42 42 40 40 40 40
1 44 43 42 41 43 42 41 40 40 40 39 39 38 38 38 37 37 36
2 41 39 37 35 41 38 37 35 37 36 34 36 35 33 35 34 33 32
3 39 36 33 31 38 35 33 31 34 32 30 33 31 30 32 31 29 29
4 36 32 30 28 35 32 29 28 31 29 27 30 28 27 29 28 26 26
5 34 30 27 25 33 29 27 25 29 26 24 28 26 24 27 25 24 23
6 32 27 24 22 31 27 24 22 26 24 22 26 24 22 25 23 22 21
7 30 25 22 20 29 25 22 20 24 22 20 24 22 20 23 21 20 19
8 28 23 21 19 27 23 20 19 23 20 18 22 20 18 22 20 18 18
9 26 22 19 17 26 21 19 17 21 19 17 21 18 17 20 18 17 16
10 25 20 18 16 24 20 17 16 20 17 16 19 17 16 19 17 16 15
Photometric Results Candlepower Distribution
Coefficients of Utilization
Cone of Light Zonal Lumens SummaryCandelas