Cooper Lighting 124T5HO Indoor Furnishings User Manual


 
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
08/02/2008 3:16:54 PM
Specifications and Dimensions subject to change without notice.
ADF032747
PHOTOMETRICS
ORDERING INFORMATION
ACCESSORIES
SHIPPING INFORMATION
2RDI
Coefficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Typical VCP Percentages
Height Along Height Across
Room Size (Ft.) 8.5' 10.0' 8.5' 10.0'
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Zonal Lumen Summary
Zone
Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
0-180
||
Candela
Angle Along II 45
o
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
2RDI-224T5RPD
Electronic Ballast
(2) F24T5HO/830
Lamps
1750 Lumens
Spacing criterion:
(II) 1.3 x mounting
height, (
) 1.3 x
mounting height
Ef
ficiency 61.7%
Test Report:
2RDI224T5RPD.IES
LER = FL39
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $6.11
631 631 631
630 630
629
622 623
625
608
612
616
588 596
604
563 576
589
533 553
570
497
525
549
457 494
524
412 460
496
364
424
466
312 385
433
257
344
398
202 302
360
150 259
318
105 215
280
65 175
242
32 134
197
0 0
0
74 74 74 74 72 72 72 72 69 69 69 66 66 66 63 63 63 62
66 62 59 56 64 61 58 55 58 55 53 55 53 52 53 52 50 49
59 53 48 44 57 52 48 44 50 46 43 48 45 42 46 43 41 39
54 46 41 36 52 45 40 36 43 39 35 42 38 35 40 37 34 33
49 41 35 30 47 40 34 30 38 33 30 37 33 29 35 32 29 27
45 36 30 26 43 36 30 26 34 29 25 33 29 25 32 28 25 23
41 33 27 22 40 32 26 22 31 26 22 30 25 22 29 25 22 20
38 29 24 20 37 29 23 20 28 23 19 27 23 19 26 22 19 18
36 27 21 18 35 26 21 17 26 21 17 25 20 17 24 20 17 16
33 25 19 16 32 24 19 16 23 19 16 23 19 15 22 18 15 14
31 23 18 14 30 22 17 14 22 17 14 21 17 14 21 17 14 13
67 75 60 69
61 66 52 58
57 60 41 46
61 65 56 62
55 58 44 48
499 14.3 23.1
827 23.6 38.3
1519 43.4 70.3
2160 61.7 100.0
2160 61.7
100.0
Coefficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Typical VCP Percentages
Height Along Height Across
Room Size (Ft.) 8.5' 10.0' 8.5' 10.0'
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Zonal Lumen Summary
Zone
Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
0-180
||
Candela
Angle Along II 45
o
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
2RDI-324T5RPD
Electronic Ballast
(2) F24T5HO/830
lamps
1750 lumens
Spacing criterion:
(II) 1.3 x mounting
height, (
) 1.3 x
mounting height
Efficiency 63.9%
Test Report:
2RDI324T5RPD.IES
LER = FL42
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $5.72
1001 1001 1001
1002 998
996
989 988
988
967 969
974
935 943
953
894 910
926
847 871
894
789 825
858
724 774
816
652 717
770
575 658
722
491 596
669
403 531
611
314 463
549
230 394
482
159 325
417
97 257
354
48
197
291
0 0
0
76 76 76 76 74 74 74 74 71 71 71 68 68 68 65 65 65 64
68 64
61 58 66 63 60 57 60 58 55 58 55 54 55 54 52 51
61 55 50 46 60 54 50 46 52 48 45 50 46 44 48 45 43 41
56 48 42 38 54 47 42 38 45 41 37 43 39 36 42 38 35 34
51 42 36 32 49 42 36 31 40 35 31 38 34 31 37 33 30 29
47 38
32 27 45 37 31 27 36 31 27 34 30 26 33 29 26 25
43 34 28 24 42 33 28 23 32 27 23 31 26 23 30 26 23 21
40 31
25 21 39 30 25 21 29 24 20 28 24 20 27 23 20 19
37 28 22 18 36 27 22 18 27 22 18 26 21 18 25 21 18 17
34 26
20 16 34 25 20 16 24 20 16 24 19 16 23 19 16 15
32 24
18 15 31 23 18 15 23 18 15 22 18 15 21 17 15 13
789 15.0 23.5
1306 24.9 38.9
2385 45.4 71.1
3353 63.9 100.0
3353 63.9 100.0
59 66 51 61
52 56 43 49
47 50 33 37
52 56 47 43
46 49 35 39
(1)
2' x 2' and 2' x 4' Center Lamp Shield models only.
SAMPLE NUMBER: 2 R D I - 2 1 4 T 5 R P D - 1 2 0 V- E B T 1- U
N u m b e r
of Lamps
(Not included)
1=1 Lamp
2=2 Lamp
3=3 Lamp
Wa tt a ge (Length)
1 4 T 5= 14WT5 (24")
(1 )
2 4 T 5=24WT5HO (24")
(1 )
Voltage
( 2)
120V=120Volt
277V=277 Volt
UNV=Universal
Voltage 120-277
Lamp Shield
R P D= Round Pe r f o r a t e d
Steel Below Ceiling Lamp
S h i e l d
R P D / T BW= Ro u n d
Perforated Below Ceiling
Lamp Shield withT h i n
BladeWhite Baff l e
TrimType
L e ave Blank= G r i d / L a y- i n
( S t a n d a r d )
2 = 2 ' W i d t h
Ovation Series
R D I=Recessed
Direct/Indirect
L e ave Blank=Center mounted
Lamps (standard)
O p t i o n s
GL=Single Element Fuse
GM=Double Element Fuse
L a m p s=Lamps installed
F l e x=Flex installed
O p t i o n s
RIF1=Radio Interference
Suppressor
EQ-Clip-U=T-Bar EQ Clip
(Order Individually as Accessory.
Use Four Per Fixture.)
DF-22-W
=Drywall Frame Kit
(Order Individually as Accessory.)
REP=Riveted Endplates, for use in
NewYork City.
ST=Semi-SpecularTannenbaum
Main Reflector
LSC=Lamp Shield Cable
Packa g i n g
U=Unit Pack
PALC=Job Pack,
in carton
BallastTy p e
( 2)
E B T =T5 Linear Electronic Program Rapid
S t a rtTotal Harmonic Distortion < 10 %
D L S=Digital Lighting System Dimming
No. of Ballast
1,2 or 3
NOTES:
Products also available in non-US voltages and
frequencies for international markets.
(2)
EQ = T-BAR Safety Earthquake Clips
(Use Four Per Fixture)
DF-22-W = Drywall Frame Kit
Catalog No. Wt.
2RDI-114T5RPD 17 lbs.
2RDI-214T5RPD 17 lbs.
2RDI-314T5RPD 17 lbs.