CFM UVHK29RN Electric Heater User Manual


 
5
20008055
The National Fuel Gas Code, ANSI Z223.1/NFPA 54
defines a confined space as a space whose volume
is less than 50 cubic feet per 1,000 Btu per hour
(4.8m
3
per kw) of the aggregate input rating of all
appliances installed in that space and an unconfined
space as a space whose volume is not less than 50
cubic feet per 1,000 Btu per hour (4.8 m
3
per kw) of
the aggregate input rating of all appliances installed
in that space. Rooms communicating directly with
the space in which the appliances are installed,
through openings not furnished with doors, are con-
sidered a part of the unconfined space.
WARNING: During manufacturing, fabricating and
shipping, various components of this appliance are
treated with certain oils, films or bonding agents.
These chemicals are not harmful but may produce
annoying smoke and smells as they are burned off
during the initial operation of the appliance, possibly
causing headaches and eye/lung irritation. This is a
normal and temporary occurrence.
WARNING: Do not use a blower insert, heat ex-
changer insert or other accessory not approved for
use with this heater.
Important Safeguards
Although your gas logs are very realistic in appear-
ance, it is not a real wood-burning fireplace and
must not be used for burning rejected material.
To avoid irreparable damage to the appliance or
personal injury; matches, paper, garbage or any other
material must not be placed or thrown on top of the logs
or into the flames.
To avoid personal injury, do not touch hot surfaces
when the appliance is operating.
Touch only the piezo button and control knob. Avoid
contact with the front screen, canopy or any other part
which will be very hot.
Always ensure that the fireplace screen is in place
when the appliance is operating and, unless other
provisions for combustion air are provided, the
screen shall have opening(s) for introduction of
combustion air.
Close supervision is necessary when the appliance
is being operated near children.
Do not use to cook food.
If this is the ONLY gas appliance, we recommend a
minimum 200 pound cylinder with a fill gauge. Use of a
100 pound cylinder is not recommended. Other house-
hold gas appliances may require the tank size to be
larger. Do not operate the vent free fireplace if the fuel
level in the propane tank is below 1/4 full.
WARNING: The glowing ember base and all the
logs are manufactured from bonded ceramic
fiber. This is a commonly used material in indus-
try worldwide. In the event of the logs and base
being removed, care should be taken not to dam-
age the bonded material.
Intentional misuse of, or deliberately fragment-
ing, the material could lead to inhaling fibers and
be injurious to health.
This appliance is intended to be used only for supple-
mental heat. Do not use it routinely as a primary
heat source. Continuous operation could produce
excessive humidity depending on construction charac-
teristics and outdoor temperatures (below 20°F). Over
time, this could cause condensation to form and dam-
age wall structures and exterior paint.
WARNING: Failure to keep primary air
opening(s) of the burner(s) clean may result in
sooting and property damage.