6"
Minimum
48"
Minimum
Ceiling
Floor
Back Wall
Corner
Wa
ll
Wa
ll
6
"
Minimum
6
"
Minimum
12"
Minimum
12"
Minimum
48"
Minimum
Ceiling
Side Wall Side Wall
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing or other flammable
objects are less than 42 inches
from the front, top or sides of
the heater
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater creates
warm air currents. These currents
move heat to wall surfaces next
to heater. Installing heater next
to vinyl or cloth wall coverings
or operating heater where impu
-
rities (such as, but not limited to,
tobacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls or cause odors.
IMPORTANT: Vent-free heaters add moisture to
the air. Although this is beneficial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Air
for Combustion and Ventilation
, page 5.
CHECK GAS TYPE
Use correct gas type (natural or propane/LP). If your gas
supply is not correct, do not install heater. Call dealer
where you bought heater for proper type heater.
WARNING: This appliance
is equipped for (natural or pro
-
pane/LP) gas. Field conversion
is not permitted.
CLEARANCES TO COMBUSTIBLES
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling and adjoining side
and back walls.
Carefully follow the instructions below. This stove
is a freestanding unit designed to set directly on the
INSTALLATION
Continued
floor. IMPORTANT: You must maintain minimum
wall and ceiling clearances during installation.
The minimum clearances are shown in Figure 4.
Measure from outermost point of stove top.
Minimum Wall and Ceiling Clearances
(see Figure 4)
A. Clearances from outermost point of stove top
to any combustible side wall should not be
less than 12 inches.
B. Clearances from outermost point of stove top
to any combustible back wall should not be less
than 6 inches (Includes corner installations).
C. Clearances from the stove top to the ceiling
should not be less than 48 inches.
Figure 4 - Minimum Clearance to Walls
and Ceiling
Front View
Top View
Side View
Front of
Stove Unit
Back Wall
Side Wall Side Wall
12 "
Minimum
12 "
Minimum
6 "
Minimum