Desa Tech CRL3124PA/NA Heating System User Manual


 
www.desatech.com
113097-01L 13
INSTALLATION
Continued
IMPORTANT: Make sure the heater burners
are level. If heater is not level, heater will not
work properly. For thermostat models, avoid
damage to thermostat bulb. Avoid nicks or
sharp bends in thermostat bulb wire. Keep
thermostat bulb in mounting bracket until
ready to mount base to oor. See Optional
Positioning Of Thermostat Sensing Bulb,
page 29.
Installation Items Needed
hardware package (provided with heater)
approved exible gas hose (not provided)
(if allowed by local codes)
sealant resistant to propane (propane/LP)
gas, not provided
electric drill with 3/16" drill bit
athead screwdriver
1. Apply pipe joint sealant lightly to male
threads of the tting to be threaded into
gas regulator. Connect approved exible
gas hose to gas regulator of heater (see
Figure 11).
IMPORTANT: Hold gas regulator with
wrench when connecting exible gas hose.
2. Locate masonry screws in hardware
package.
3.
Position heater base assembly in replace.
4. Place logs in their proper position on heater
base, see Installing Logs on page 16.
5. Center heater base and logs front-to-back
and side-to-side in replace.
6. Carefully remove logs without moving
heater base.
7. Mark screw locations through holes in
mounting brackets (see Figure 12 and
13). If installing in a brick-bottom replace,
mark screw locations in mortar joint of
bricks.
8. Remove heater base from replace.
9. Drill holes at marked locations using 3/16"
drill bit.
10. Attach base assembly to replace oor
using two masonry screws (in hardware
package) (see Figure 12 or 13).
Figure 11 - Attaching Flexible Gas Hose
to Heater Gas Regulator
Figure 12 - Attaching Base Assembly to
Fireplace Floor - Dual Burner Model
Heater Gas
Regulator
Flexible Gas Hose
(if allowed by local codes)
Fitting
Masonry
Screw
Mounting
Bracket
Masonry
Screw
Figure 13 - Attaching Base Assembly to
Fireplace Floor - Single Burner Model
Mounting
Bracket
CONNECTING TO GAS SUPPLY
WARNING: This appliance
requires a 1/2" NPT (National
Pipe Thread) inlet connection to
the pressure regulator.
WARNING: A qualied ser-
vice person must connect heater
to gas supply. Follow all local
codes.