Desa Tech CGN10TL Indoor Fireplace User Manual


 
10
103574
Figure 5 - Mounting Screw Locations
Mounting
Screw
Locations
8 7/8"
Minimum To
Maintain 6"
Clearance
From Wall
7 3/4"
20 1/4"
Minimum To
Maintain 3"
Clearance
From Floor
FLOOR
JOINING WALL
INSTALLING HEATER TO WALL
Marking Screw Locations
1. Determine where you will locate heater.
2. Mark two mounting screw locations on wall (see Figure 5).
INSTALLING TO
WALL
Continued
WARNING ICON G 001
WARNING
Maintain minimum clearances shown in Figure 5. If you can,
provide greater clearances from floor and joining wall.
For convenience and efficiency, install heater
• where there is easy access for operation, inspection, and service
• in coldest part of room
Figure 4 - Mounting Clearances As Viewed From Front of Heater
36"
3"
FLOOR
CEILING
Minimum
Minimum To Top Surface
Of Carpeting, Tile Or Other
Combustible Material
6"
Minimum
From
Sides Of
Heater
Right
Side
Left
Side
THERMOSTAT SENSING BULB
The thermostat sensing bulb is located inside the heater. Do not move this bulb
during installation or operation of the heater.