Desa Tech CGD3930P Indoor Fireplace User Manual


 
15
102991
INSTALLING
Continued
CONNECTING TO GAS SUPPLY
NOTICE
A qualified service person must connect heater to gas supply.
Follow all local codes.
WARNING ICON G 001
CAUTION
Never connect heater directly to the propane supply. This heater
requires an external regulator (not supplied). Install the external
regulator between the heater and propane supply.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
external regulator (supplied by
installer, see page 16)
piping (check local codes)
sealant (resistant to propane/LP gas)
manual shutoff valve *
test gauge connection *
sediment trap
tee joint
pipe wrench
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See Accessories, page 33.
Continued
Masonry Screw
Mounting
Bracket
Figure 12 - Attaching Base Assembly to Fireplace Floor