036-21603-002 Rev. A (1004)
4 Unitary Products Group
NOTES
1. Airflow expressed in standard cubic feet per minute (CFM) and in cubic meters per minute (m
3
/min).
2. Motor voltage at 115 V.
* Input / CFM / Cabinet Width (A=14-1/2, B=17-1/2, C=21, D=24-1/2).
TABLE 1: Blower Performance CFM - Upflow (without filter) - Bottom Return
MODELS
Input /
CFM
Speed
Two Stage Bottom Airflow Data (SCFM)
Ext. Static Pressure (in. H2O)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
(F,L)C8T060A12UH11
High 1570 1490 1420 1340 1250 1180 1090 990 870 700
Medium High 1410 1360 1310 1250 1190 1090 1020 920 810 650
Medium Low 1200 1180 1150 1100 1050 990 920 830 700 580
Low 960 960 950 930 900 840 800 720 610 500
(F,L)C8T080A12UH11
High 1590 1520 1460 1380 1300 1240 1150 1050 930 800
Medium High 1400 1360 1310 1260 1200 1140 1070 960 860 740
Medium Low 1180 1160 1130 1090 1040 990 920 840 750 640
Low 940 940 940 920 880 840 790 710 630 530
(F,L)C8T080B16UH11
High 1850 1820 1790 1750 1690 1630 1570 1500 1430 1330
Medium 1470 1450 1440 1430 1390 1360 1310 1270 1220 1150
Low 1260 1260 1260 1260 1250 1200 1150 1110 1070 1010
FC8T100B12UH11
High 1700 1620 1560 1480 1390 1300 1210 1110 970 820
Medium High 1430 1400 1350 1300 1230 1160 1080 980 870 710
Medium Low 1180 1170 1160 1130 1080 1030 1000 860 750 510
Low 950 950 930 920 880 840 790 720 620 530
(F,L)C8T100C20UH11
High 2590 2500 2400 2280 2180 2080 1970 1840 1720 1560
Medium High 2180 2120 2040 1980 1900 1810 1720 1600 1480 1320
Medium Low 1750 1720 1680 1640 1580 1520 1440 1350 1220 1060
Low 1450 1420 1380 1330 1300 1240 1160 1070 970 860
FC8T120C16UH11
High 2020 1930 1820 1730 1640 1540 1400 1250 1090 920
Medium 1750 1710 1650 1590 1490 1390 1290 1160 1010 810
Low 1540 1500 1460 1410 1350 1260 1180 1060 910 750
FC8T120C16UH11
High 2500 2400 2320 2220 2110 2000 1870 1750 1610 1450
Medium High 2130 2070 1990 1920 1840 1760 1660 1570 1460 1320
Medium Low 1700 1680 1650 1620 1560 1500 1410 1320 1210 1070
Low 1420 1390 1360 1330 1290 1240 1150 1060 950 840