Cleveland Range GFB-6 Boiler User Manual


 
SECT. XIV PAGE 54
0907
Litho in USA
Cleveland Range reserves right of design improvement or modification, as warranted.
F
H
CAN PIVOT 360∞
GAS HEAD
E
(TO OUTSIDE
1
-1/4" DIA. VENT
3
" DIA. VENT
(TO OUTSIDE
O
F BUILDING)
G
C
D
4 1/4"
B
(PIPE TO DRAIN)
O
VERFLOW
OVERALL
REMOVAL
B
URNER
S
AFETY VALVE
E
XHAUST
4 1/4"
STEAM GAGE ASSEMBLY
A
B
OILER HEIGHT
W
ITH TRIM
(NOT SUPPLIED)
SHUTOFF VALVE
G
AS INLET
G
AS INLET
OF BUILDING)
FRONT VIEW
PLAN VIEW
2
1
2
CR
D
MINIMUM CLEARANCE
FRONT 18"
SIDES 18"
REAR 18"
TOP - see dimension "C"
DIMENSIONS
MODEL ABCDEFGH
GFB-6 75" 72" 86 1/4" 56 1/4" 48" 33" 44" 22 1/2"
GFB-10 80 1/2" 78" 90 1/4" 62 1/4" 54" 33 1/2" 46" 21 1/2"
GFB-15 86 1/2" 84" 96 1/4" 67 1/4" 54" 35 1/2" 47" 20 1/2"
GFB-20 92 1/2" 90" 100 1/4" 70 1/4" 54" 43" 60" 25"
GFB-30 102" 96" 110 1/4" 77 3/4" 60" 49" 67" 27"
GFB-50 106 1/2" 114" 118 1/4" 83 1/4" 66" 57" 78" 22 1/2"
GFB-60 120" 114" 128 1/4" 89 1/4" 66" 57" 78" 34"
UTILITY CONNECTIONS
120/1PH
BOILER BLOW DOWN STEAM CONDEN
NATURAL GAS
EL1 EL2
FILL COLD OUTPUT
-SATE
BLOWDOWN
CONSUMPTION
ELEC- FOR
MODEL COLD WATER WATER
STEAM LBS/HR
RETURN DRAIN GAS FT
3
/HR TRICAL PUMP
GFB-6 1/2" NPT 1" NPT 3/4" 207 1" 1 1/2" 1" 260 5.2 10
NPT NPT NPT NPT AMPS AMPS
GFB-10 1/2" NPT 1" NPT 1" 345 1 1/4" 1 1/2" 1" 420 5.2 10
NPT NPT NPT NPT AMPS AMPS
GFB-15 1/2" NPT 1 1/4" NPT 1 1/4" 518 1 1/4" 1 1/2" 1 1/4" 630 5.2 15
NPT NPT NPT NPT AMPS AMPS
GFB-20 1/2" NPT 1 1/4" NPT 1 1/2" 690 1 1/4" 1 1/2" 1 1/4" 840 9.2 15
NPT NPT NPT NPT AMPS AMPS
GFB-30 1/2" NPT 1 1/4" NPT 2" 1035 1 1/4" 1 1/2" 1 1/2" 1260 9.2 20
NPT NPT NPT NPT AMPS AMPS
GFB-50 3/4" NPT 1 1/2" NPT 3" 1725 2" 1 1/2" 1 1/2" 2100 **4.4 **11
NPT NPT NPT NPT AMPS AMPS
GFB-60 3/4" NPT 2" NPT 3" 2070 2" 1 1/2" 2" 2520 **4.4 **16.7
NPT NPT NPT NPT AMPS AMPS
** 208V / 3PH
D
1 D
2
B
D
1 D
2
B
D
1 D
2
B
D
1 D
2
B
D
1 D
2
B
D
1 D
2
B
D
1 D
2
B
12
(NOT TO SCALE)
2
D
1 D
2
B
1
NOTE: It is the owners/operators responsiblity to meet the recommended minumum water quality requirements.