Clarke 14 Vacuum Cleaner User Manual


 
Page 26 Clarke
®
CombiVac 12 & 14 Operator's Manual
Figure18
Figure 19
How To Change the Drive Belt
To change the drive belt, follow this procedure:
1. Put the machine on its side.
2. Remove the nozzle plate.
3. Remove the brush assembly. See figure 18.
4. Remove the drive belt from the pulley.
5. Remove the drive belt from the motor shaft.
6. Put one end of the new drive belt around the
motor shaft.
7. Put the other end of the drive belt around the
spacer.
8. Install the brush assembly in the motor housing.
9. Install the nozzle plate.
10. Put the machine on its wheels.
WARNING: To reduce the risk of injury from
moving parts, unplug before servicing.
ATTENTION: Pour ériter d'être blessé pour les
piéces en mouvement, déiancher avant la
maintenance.
The Indicator Light
If the indicator light (1) comes on, see figure 19, or the
motor stops, do the following:
1. Put the ON/OFF switch in the "O" position (2).
2. Remove the electrical plug from the electrical
outlet.
3. Check the vacuum hose for an obstruction. If
there is an obstruction in the vacuum hose,
remove the obstruction.
4. Check the brush assembly in the lower housing.
If there is an obstruction in the brush assembly,
remove the obstruction.
5. Check the filter bag. If the filter bag is full,
change or empty the bag.
6. Check the motor filter. If the motor filter is dirty,
clean the motor filter.
The Circuit Breaker
A circuit breaker is used to protect the vacuum motor.
If the motor draws high amperage, the circuit breaker
will stop the motor. If the motor stops, let the motor
cool before restarting the machine. If the motor
continues to stop, consult an authorized service
person.