MOUNTING
1. Locate heater position on wall. This unit has special baffle plates
and vent holes in the cover to ensure sufficient convection currents.
Make sure that the heater is mounted so that the mounting label
located on the end cover points up (Fig. 1).
2. To locate mounting holes, see Specifications Table for heater in
question. In standard 16” stud center frame construction, locate
wall studding and locate 1 upper and 1 lower mounting hole in
center of stud.
3. Drill a pilot hole in metal or wood surfaces using a convenient
small size drill.
4. Drill the 4 holes in accordance with sizes in Table 1. Insert anchors
where applicable.
5. Remove cover screws.
6. Remove cover.
7. Fasten to wall with screws as listed in Table 1. Turn tight and then
back off 1/2 turn, to allow for expansion and contraction.
8. Replace heater cover — fasten with screws and washers removed
in Step 5.
Screw Size to Fit Hole Size
** in Heater Mounting Plates
Type Mounting Accessory ScrewDrill Size
Surface Hardware Type and Type Terminal End Opposite End
Round Head
Ackerman
Mach.Steel
1/2” Masonry 1/4 x 20 x 3” 1/4 x 20 x 2”
Concrete, Block Round Head. Mach.
Masonry
Lead Anchor
Steel or Pan
3/8” Masonry #14 x 3” #14 x 2”
Head Metal
(Self-tapping)
Wood Studs
Wood or Metal
#14 x 3” #14 x 2”
(Self-tapping)
Plaster Wall
Hollow or Toggle Bolt #7 1/4 x 4” 1/4 x 3”
Similar Type
* Metal Beam, Round Head
Channel, etc.
Nuts, Washers
Mach. Steel
#7 Twist 1/4 x 20 x 1-11/16”* 1/4 x 20 x 13/16”*
Table 1 — Suggested Heater Mounting Screws (Types and Sizes)
* If clearance permits, use washer, lockwasher and nut; otherwise, drill and tap. To these lengths add thickness of beam, washers, nut, etc.
** If mounting structure permits, except plastered hollow walls, explosive type anchors can be used. Suggest sizes noted in Table and/or sketches be used to determine size
of anchors.
Figure 1 - Mounting
4" Machine Screw
(
4 Pls
.
)
B
A
Model
Dimensions (In.)
AB
H-1801 5-3/4 19-1/2
H-2405 5-3/4 25
H-2406 9-7/8 25
H-2407 9-7/8 25
Heater Mounting Dimensions (In.)
Fire Hazard
• Not suitable for household or
residential use.
• Do not cover.
• Keep combustible material
away from heater.
• Do not recess heater into
wall.