Chauvet DMX-750 Home Safety Product User Manual


 
OPERATING INSTRUCTIONS
DMX-750 Manual Version 1.1 9
Example 1:
Starting address (233)
illustrated.
Example 2:
Resolving starting address (233)
using simple math.
233 – (128) = 105, Turn ON Dip # 8
105 – (64) = 41, Turn ON Dip # 7
41 – (32) = 9, Turn ON Dip # 6
9 – (8) = 1, Turn ON Dip # 4
1 – (1) = 0, Turn ON Dip # 1
Turn ON Dip # 10 to activate DMX Mode
You will most likely use the first available
address. This number was selected for example
purposes.
Dip Switch (DMX Value)
1
2
3
4
5
6
7
8
9
10
1
2
4
8
16
32
64
128
256
ON = Activate
DMX Control
Self-Test Mode
With Dip Switch # 10 set to the OFF position the following assignments will result in the playback of pre-
programmed test patterns.
MANUAL AUTO
Dip Switch Function Dip Switch Function
9 ON 9 OFF
1 – 4 SPEED
5 – 8 INTENSITY
1 – 8 RANDOM
Enhanced Settings for Test Mode
Level Dip Switches 1 – 4
Reflects ON
position all others
OFF
Speed Level Dip Switches 5 -8
Reflects ON
position all others
OFF
Intensity
1 - Slowest 1 - Bright
2 1 2 5
3 2 3 6
4 1, 2 To 4 5, 7 To
5 3 5 7
6 1, 4 6 5, 8
7 2, 3 7 6, 7
8 1, 2, 3 Fastest 8 5, 6, 7 Brightest
Table continued on next page.
1 2 3 4 5 6 7 8 9 10
(1)
(2)
(4)
(8)
(16)
(32)
(64)
(128)
(256)
SWITCH
DMX
VALUE
OFF
ON