re-tightenthelockingnut.Ensurethat
theflapopensandclosesfreelyasthe
knobisturned.
Beforeinitiallightingthefollowing
pointsshouldbechecked:-
1.Thebottomgratebarsmustallbe
fittedandshouldmovefreelyand
easilywhentheriddlingmechanismis
operated.
2.Theplatesroundthesidesandback
ofthegratemustbeinpositionand
sittingcorrectly.
PRELIGHTING
CHECK
3.Thethroatplatemustbefittedinthe
roofoftheapplianceandshouldbe
checkedtoensurethatithasnot
becomedislodgedintransit.The
methodoflocationandpositioningof
thethroatplateisshowninFig.3.
Oncompletionoftheinstallationand
afterallowingasuitableperiodoftime
forthefirecementandmortartodry
out,thestoveshouldbelitand
checkedtoensurethatsmokeand
fumesaretakenfromtheapplianceup
thechimneyandemittedsafely.Also
checkalljointsandseals.
COMMISSIONING
Thecentralheatingpumpshouldbe
adjustedtogivethecorrectwaterflow
againstthecircuitresistanceandthe
systemshouldbecorrectlybalanced.
Oncompletionoftheinstallationand
commissioningpleaseleavethe
operatinginstructionswiththe
customerandadviseontheuseofthe
applianceandanycontrolsonthe
system.
Country14BDimensions
(Alldimensionsareinmm)
Page8
Country14B09/03
Flueconnectionmay
beToporRear
357
340
616
570
601
ø154
731
389
136
683
451
344136
789
136
608
Boilertappingsare1"BSPFemale