Chamberlain PD432D 1/2 HP Garage Door Opener User Manual


 
31
To Open the Door Manually
DISCONNECT THE TROLLEY:
The door should be fully closed if possible. Pull down on
the emergency release
handle (so that the trolley
release arm snaps into a
vertical position) and lift the
door manually.
The lockout feature prevents
the trolley from reconnecting
automatically, and the door
can be raised and lowered
manually as often as necessary.
TO RE-CONNECT THE
TROLLEY:
Pull the emergency release
handle toward the opener at
an angle so that the trolley
release arm is horizontal.
The trolley will reconnect on
the next UP or DOWN
operation, either manually or by
using the door control or remote.
To prevent possible SERIOUS INJURY or DEATH from a
falling garage door:
If possible, use emergency release handle to disengage
trolley ONLY when garage door is CLOSED. Weak or
broken springs or unbalanced door could result in an open
door falling rapidly and/or unexpectedly.
NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
NEVER use handle to pull door open or closed. If rope knot
becomes untied, you could fall.
WARNING
CAUTION
WARNING
WARNING
Lockout position
(Manual disconnect)
NOTICE
Emergency
Release Handle
(Pull at 45° angle)
Trolley
Release
Arm
Trolley
N
O
T
I
C
E
Trolley Release
Arm (in Manual
Disconnect Position)
Trolley
To reconnect
Using the Wall-Mounted Door Control
THE MULTI-FUNCTION DOOR
CONTROL
Press the lighted push button to
open or close the door. Press again
to reverse the door during the
closing cycle or to stop the door
while it's opening.
Light feature
Press the Light button to turn the opener light on or off. It
will not control the opener lights when the door is in
motion. If you turn it on and then activate the opener, the
light will remain on for 4-1/2 minutes. Press again to turn
it off sooner. The 4-1/2 minute interval can be changed to
1-1/2, 2-1/2, or 3-1/2 minutes as follows: Press and hold
the Lock button until the light blinks (about 10 seconds).
A single blink indicates that the timer is reset to 1-1/2
minutes. Repeat the procedure and the light will blink
twice, resetting the timer to 2-1/2 minutes. Repeat again
for a 3-1/2 minute interval, etc., up to a maximum of four
blinks and 4-1/2 minutes.
Lock feature
Designed to prevent operation of the door from
hand-held remote controls. However, the door will open
and close from the Door Control, the Outdoor Keylock
and the Keyless Entry Accessories.
To activate, press and hold the Lock button for 2
seconds. The push button light will flash as long as the
Lock feature is on.
To turn off, press and hold the Lock button again for
2 seconds. The push button light will stop flashing. The
Lock feature will also turn off whenever the “learn” button
on the motor unit panel is activated.
Additional feature when used with the 3-Button
hand-held remote
To control the opener lights:
In addition to operating the door, you
may program the remote to operate the
lights.
1. With the door closed, press and hold
a small remote button that you want
to control the light.
2. Press and hold the Light button on the door control.
3. While holding the Light button, press and hold the Lock
button on the door control.
4. After the opener lights flash, release all buttons.
L
O
C
K
L
I
G
H
T
Lighted
Push Button
Lock
Button
Light
Button