STEP 2
Adjust Force
DO NOT USE FORCE ADJUSTMENTS TO COMPENSATE FOR A BINDING OR STICKING GARAGE DOOR.
EXCESSIVE FORCE WILL INTERFERE WITH PROPER OPERATION OF SAFETY REVERSE SYSTEM OR DAMAGE
GARAGE DOOR.
Force Adjustment Controls are located on rear panel of opener.
FORCE ADJUSTMENT settings regulate amount of the power
required to open and close door.
NOTE: The door STOPS in the UP direction if anything
interferes with its travel. Door REVERSES in the DOWN
direction if anything interferes with its travel (including
binding or unbalanced doors).
If the force adjustments are set too light, door travel may be
interrupted by nuisance reversals in DOWN direction and stops in
UP direction. As weather conditions can affect the door movement,
occasional adjustment may be needed.
Maximum force adjustment range is 260 degrees, about 3/4 of a
complete turn. Do not force controls beyond that point. Turn force
adjustment controls with a screwdriver.
FORCE ADJUSTMENT CHART
TEST DOWN (CLOSE) FORCE
IF DOOR DOESN'T OPEN AT LEAST 5 FEET
Grasp the door handle or door bottom when door is about halfway
through DOWN (CLOSE) TRAVEL. Door should reverse. If the
door is hard to hold or doesn't reverse, decrease DOWN (CLOSE)
FORCE by turning the control in a counterclockwise direction.
Make 10 degree turn adjustments until door reverses normally.
After each adjustment, run opener through a complete cycle.
PROCEED TO STEP 3
Increase UP (OPEN) FORCE by turning clockwise. Make 10
degree turn adjustments until door opens completely. Readjust UP
LIMIT if necessary. After each adjustment, run opener through a
complete travel cycle.
IF DOOR REVERSES DURING DOWN (CLOSE) CYCLE
Increase DOWN (CLOSE) FORCE by turning control clockwise.
Make 10 degree turn adjustments until door completes close
cycle. After each adjustment, run the
opener through a complete travel travel
17
Adjsutment Label
Adjustment Force
Controls