Chamberlain 3800C Garage Door Opener User Manual


 
23
CARE OF YOUR OPENER
MAINTENANCE SCHEDULE
Once a Month
• Manually operate door. If it is unbalanced or binding,
call a trained door systems technician.
• Check to be sure door opens & closes fully. Adjust
limits and/or force if necessary (see Adjustment Steps 1
and 2).
• Repeat the safety reverse test. Make any necessary
adjustments. (see Adjustment Step 3)
Once a Year
• Oil door rollers, bearings and hinges. The opener does
not require additional lubrication. Do not grease the
door tracks.
THE REMOTE CONTROL BATTERY
The lithium battery should
produce power for up to
5 years. To replace battery,
use the visor clip or
screwdriver blade to pry open
the case as shown. Insert
battery positive side up.
Dispose of old battery properly.
Battery
positive
side up (+)
3.The door operates from the Control Console, but
not from the remote control:
Is the door push bar flashing? If so, Lock mode is
engaged. Make sure it is off by pressing the
Lock button.
Program the opener to match the remote control code.
(Refer to instructions on the motor unit panel.) Repeat
with all Remote.
4. The remote control has short range:
Change the location of the remote control in your car.
Check to be sure the antenna on the side or back
panel of motor unit extends fully downward.
Some installations may have shorter range due to a
metal door, foil backed insulation, or metal
garage siding.
HAVING A PROBLEM?
(TROUBLESHOOTING)
1.The opener doesn't operate from either the Control
Console or the remote control:
Does the opener have electric power? Plug a lamp
into the outlet. If it doesn't light, check the fuse box or
the circuit breaker. Some outlets are controlled by a
wall switch.
Have you disabled all door locks? Review installation
instruction warnings on page 7.
Is there a build-up of ice or snow under the door? The
door may be frozen to the ground. Remove any
restriction.
The garage door spring may be broken. Have it
replaced.
2. Opener operates from the remote, but not from the
Control Console:
Is the control console lit? If not, reverse the wires. If
the opener runs, check for a faulty wire connection at
the control console, a short under the staples, or a
broken wire.
Are the wiring connections correct? Review Installation
Step 5, page 10.
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of
this receiver and/or remote control are prohibited, except for changing the code setting or
replacing the battery. THEREARE NO OTHERUSER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
WARNING
CAUTION
WARNING
WARNING