ONE-PIECE DOOR WITHOUT TRACK
With the door fully open and parallel to the floor,
measure the distance from the floor to the top of
the door.
Using a stepladder as a support, raise the top of
the opener to this height.
The top of the door should be level with the top of
the motor unit. Do not position the opener more
than 2" (5 cm) above this point.
INSTALLATION STEP 4
Position the Opener
Follow instructions which apply to your door type as
illustrated.
SECTIONAL DOOR OR ONE-PIECE DOOR WITH
TRACK
A 2x4 laid flat is convenient for setting an ideal door-
to-rail distance.
Raise the opener onto a stepladder. You will need
help at this point if the ladder is not tall enough.
Open the door all the way and place a 2x4 laid flat
on the top section beneath the rail.
If the top section or panel hits the trolley when you
raise the door, pull down on the trolley release arm
to disconnect inner and outer sections. Slide the
outer trolley toward the motor unit. The trolley can
remain disconnected until Installation Step 12
is completed.
2x4
laid flat
Rail
Door
Trolley
Release Arm
ENGAGED
RELEASED
To prevent damage to garage door, rest garage door
opener rail on 2x4 placed on top section of door.
WARNING
CAUTION
WARNING
WARNING
Top of Opener
Header
Bracket
Top of door