Chamberlain 1210E FS2 Garage Door Opener User Manual


 
Figure 4 REMOVE COVER
INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of the door at a
minimum height of 1.5 m where small children cannot
reach, and away from moving parts of the door and
door hardware. The installation surface must be smooth
and flat. If installing into drywall (Figure1), drill 4 mm
holes and use anchors provided. For pre-wired
installations (as in new home construction), it may be
mounted to a single gang box (Figure 2).
NOTE: After installation, a green indicator light behind
the cover will indicate proper connection. If not lit, the
Lock and Light features will not function (reverse wires
to correct).
1. Strip 11 mm of insulation from one end of bell wire
and connect to the two screw terminals on back of
door control by color: white wire to 2 and white/red
wire to the 1 (Figure 3).
2.
Model 1210E - Lighted door control:
Remove the
cover from the Lighted Door Control.
Fasten to wall
with 6ABx1-1/2" self-tapping screws (Figure 4)
Model 1220E - Multi-function door control:
Remove
white cover by gently prying at slot in top of the cover
with a small flat head screwdriver. Fasten with
6ABx1-1/4" self-tapping screws (drywall installation)
or 6-32x1" machine screws (into gang box) as
follows:
• Drill and install bottom screw, allowing 3 mm to
protrude above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
• Install top screw with care to avoid cracking plastic
housing. Do not overtighten.
• Insert bottom tabs and snap on cover.
3. (Standard installation only) Run bell wire up wall
and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.
4. Strip 11 mm of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red (Figure 5).
NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires
into quick-connect holes: white to white and red/white
to red.
5. Use tacks or staples to permanently attach
entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.
WIRING INSTRUCTIONS FOR ACCESSORIES
The Protector System
®
: To opener terminals: White to
White and Black to grey.
Outside Keylock Accessory connections: To opener
terminals: Red/white to Red and White to White.
2
1
RED
WHT
Bell Wire
Terminal
Screws
Bottom Mounting Hole
Top Mounting Hole
W
H
T
-2
RED
-1
6ABx1-1/2" Screw
Lighted Door Control Button
Drywall
Anchors
Insulated
Staples
6ABx1-1/4" Screw
Multi-function (std installation)
6-32x1" Screw
Multi-function (pre-wired)
HARDWARE SHOWN ACTUAL SIZE
Figure 2
To Replace
Insert Bottom Tabs First
PRE-WIRED
INSTALLATION
24 Volt
Bell Wire
L
O
C
K
L
I
G
H
T
L
O
C
K
L
IG
H
T
To Replace
Insert Bottom Tabs First
Figure 1
STANDARD
INSTALLATION
Single
Gang Box
Figure 3 DOOR CONTROL (BACK)
Figure 5
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 1.5 m, and away
from all moving parts of door.
• NEVER permit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
WARNING
CAUTION
WARNING
WARNING
To release wire, push in tab
with screwdriver tip
Door Control
Connections
11 mm
Strip wire 11 mm
Red
Grey
White
KG
1
3
9
7
5
KG
1
3
9
7
5
22