Vermont Casting VCPV18TP - 18 Gas Heater User Manual


 
9
Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater
Pilot and Burner Inspection
Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in
Figures 9, 10 and 11. If flame patterns are incorrect,
turn the heater off. Contact your dealer or a qualified
gas technician for assistance. Do not operate the
heater until the pilot flame is correct.
WARNING: If yellow tipping occurs, your heater could
produce increased levels of carbon monoxide. If burner
flame pattern shows yellow tipping, follow instructions
in the Troubleshooting section on page 10. NOTE: do
not mistake orange flames with yellow tipping. Dirt or
other particles may enter the heater and cause tran-
sient patches of orange flame.
Ignitor Electrode
Thermocouple
Correct
Incorrect
Fig. 9 Proper pilot flame.
P103
Manual Lighting Instructions
1. Remove lower front panel.
2. Follow steps 1 through 4 as stated under Lighting
Instructions.
3. Press and turn control knob counterclockwise
to the PILOT position.
4. With control knob pressed in, strike match, hold
match to pilot until pilot lights.
5. Keep control knob pressed in for 30 seconds after
lighting pilot. After 30 seconds, release control knob.
6. Replace lower front panel.
Correct
Incorrect
RH109
Fig. 11 Correct burner flame pattern for the VCPV plaque
heater.
VCPV Heater
VCBV Heater
Yellow Tipping
Correct Incorrect
Fig. 10 Correct burner flame pattern for the VCBV blue flame
burner.
RH106