Vermont Casting SA30SKHRN Indoor Fireplace User Manual


 
4
3311857
CAUTION: If you answered “NO” to any item, or have any questions regarding your installation, please
contact your dealer/distributor for assistance.
Is the gas supply inlet pressure correct?
NG: Min. 5.5” w.c./Max. 14.0” w.c. LP: Min. 11” w.c./Max. 14.0” w.c.
Does the firebox meet the minimum size dimensions below?
Is your fireplace plumbed with gas on the right side (facing) of the fireplace?
If not, refer to ee Page 5
Is the gas supply line sized properly (Minimum 1/2” iron pipe)?
Do you have a solid fuel (wood burning) fireplace with a vented flue?
Do you have a manual gas supply valve installed at your fireplace? If not, a licensed
plumber, gas company technician or other qualified installer must install one.
Have you checked local building codes? (Check with your local building department)
Does your fireplace have a wire mesh screen in place?
Pre-Installation Checklist Yes No
Minimum Clearances & Specifications
Natural Gas Units
Propane Gas Units
Size Btu/hr Back Front Depth Height Size Minimum Maximum”
18” 45,000 16” 33” 15” 18” 51 sq.in. 5.5”w.c. 14.0”w.c. 3.5”w.c.
24” 60,000 20” 36” 15” 18” 51 sq.in. 5.5”w.c. 14.0”w.c. 3.5”w.c.
30” 60,000 27” 39” 15” 18” 51 sq.in. 5.5”w.c. 14.0”w.c. 3.5”w.c.
Minimum Firebox Dimensions Minimum Gas Fuel Line Manifold
Set Input Width Flue Pressure Pressure
Size Btu/hr Back Front Depth Height Size Minimum Maximum
18” 40,000 16” 33” 15” 18” 51 sq.in. 11.0”w.c. 14.0”w.c. 10.0”w.c.
24” 45,000 20” 36” 15” 18” 51 sq.in. 11.0”w.c. 14.0”w.c. 10.0”w.c.
30” 60,000 27” 39” 15” 18” 51 sq.in. 11.0”w.c. 14.0”w.c. 10.0”w.c.
Minimum Firebox Dimensions Minimum Gas Fuel Line Manifold
Set Input Width Flue Pressure Pressure
NOTE: All dimensions are minimums.