The Damper Clamp provided keeps your damper
from accidentally closing during operation of your
set. This Damper Clamp must be installed
onto your Damper at all times. NOTE: The
damper clamp is designed to hold the damper
plate open 3 inches. However, the damper
must be fully open when the log set is in op-
eration.
Install the Damper Clamp onto the edge of the
damper plate. Attach by securing the bolt provid-
ed to the damper plate with an adjustable wrench.
(Fig. 3)
If the Damper Clamp does not fit, drill a 1/4” hole
into the damper plate and install an anchor bolt
with nut, at a 90 degree angle, so that the damper
plate will remain fully open.
The proper finished installation of the Damper
Clamp is shown in Figure 4. If the bolt fails to
block the damper in an open position, the damper
should be removed from the chimney.
To check your vent for proper drafting:
Light a
tightly rolled newspaper on one end and place it at
the inside front edge of the fireplace. Observe the
smoke and be sure the vent is properly drawing it
up the chimney. If the smoke is drawn back into
the room, extinguish the flame and remove any
obstruction until proper venting is achieved. If that
fails, check with a qualified chimney sweep.
Damper Stop Installation:
For Use With All Other Fireplaces
DP104
Damper clamp
Harris
Figure 3
Damper Plate
Damper Clamp
DP104
DP103
Damper clamp
Harris
Figure 4
Chimney
Clamp
Damper
DP103