Vermont Casting RHE25 Indoor Fireplace User Manual


 
12
10000836
Vermont Castings, Majestic Products RHE Natural Vent Insert
JR5
JR2
KR1
JR3
JR4
JR6
Burner Lava Rock
Placement
Fig. 17 RHE25 log and lava rock placement.
LG279
KR5
KR6
KR4
KR3
KR1
KR2
Burner Lava Rock
Placement
LG280
Fig. 18 RHE32 log and lava rock placement.
SR5
SR2
SR6
SR3
SR4
SR1
Burner Lava Rock
Placement
LG281
Fig. 19 RHE42 log and lava rock placement.
Large Lava Rock Placement
The large lava rock provided with this fireplace must be
placed on the firebox base on either side of the burner
assembly.
Under no circumstances should these
lava rock be placed on top of the burner
assembly.
For fireplaces equipped with HI/LO valve, flame adjust-
ment is accomplished by rotating the HI/LO adjustment
knob located near the center of the gas control.
(Figs. 20 & 21)
Flame Adjustment (RN/RP Models)
LO
HI
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
Fig. 20 Flame adjustment knob for Honeywell Valve.
L
O
H
I
Turn
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
Fig. 21 Flame adjustment knob for SIT Valve.
Temperature Adjustment (TN/TP Models)
The HI/LO reference on the control knob (Fig. 22) is to
indicate a higher or lower temperature setting. This
setting controls the heat by reducing then shutting off
the flame after the desired temperature is reached.
Position the control knob where it effectively maintains
a comfortable room temperature.
Fig. 22 Temperature adjustment knob for TN/TP models.
Flame Characteristics
It is important to periodically perform a visual check of
the pilot and the burner flames. Compare them to
Figure 23 and Figure 24 or 25. If any of the flames
appear abnormal, call a service person.