10
10009816
• Glass Information
1. Under no circumstances should this product be operated with broken glass.
2. Do not strike or slam the glass.
3. Do not use abrasive cleaners to clean the glass.
4. This product uses tempered glass. Replacement of the glass supplied by the manufac
-
turer should be done by a qualified service person.
• Replacing the Light Bulbs
Depending on your model, the fireplace uses two (2) or three (3) clear 120 Volt, 60 Watt,
E-12 socket base light bulbs (small base, chandelier candle type) located under the
ember bed. Units with overhead lights (Fig. 10) use two (2) clear 120 Volt, 5 Watt, E-12
socket base light bulbs (small base, chandelier candle type) located above the logs. For
convenience, if one of the light bulbs burns out, it may be easier to replace all of the light
bulbs at the same time.
Do not exceed 60 Watts per bulb for the ember bed bulbs and 5 Watts per bulb for
the overhead lights. Use of higher rated bulbs may result in a fire, causing property
damage, personal injury or loss of life.
1. Turn off power to the unit.
2. Let fireplace cool if it has been operating.
3. Open the front doors.
4. Remove the door hat bracket by removing the center screw. (Fig. 2) Slowly open doors
and remove bracket from between the inner and outer door frame. (Fig. 3) (Retain
bracket)
5. To remove the doors, locate and remove the two (2) screws holding the door at the
top. (Fig. 3) Hold the door at all times with one hand to prevent the door from falling
when you undo the hinge screws.
6. Locate two (2) screws that hold the refractory (brick patterned) bracket together with
the ember bed. (Fig. 7)
NOTE: Some units may have two (2) screws securing the
refractories to the ember bed. These screws must also be removed. (not shown)
Remove Screws
Figure 7
FP1737
7. Remove those two (2) screws using an appropriate screw-
driver. One screw is located on either side of the unit.
8. Pull the ember bed out of the unit by gently pulling towards
you and only slightly upwards. Depending on the model, you
can remove the refractory prior to removing the ember bed.
Pull Here
(both sides)
Figure 8
FP1738