Vermont Casting BR42 Indoor Fireplace User Manual


 
15
Majestic Fireplaces® BR/BC Series
7412944
MA81
rev. 8/5/97
1¹⁄₂"
Ref.
Combustible materials are
permitted within a shaded area
shown in Figure 23 titled
Minimum Wall Clearances.
*
**
MA81
Fig. 22 Combustible mantel clearances.
*12" from top of fireplace opening for radiant models
12" from top of grille opening for circulating models
**6" from top of fireplace opening for radiant models
(Noncombustible material must seperate the black
face surround of the fireplace from any combustible
mantel material)
6" from top of grille opening for circulating models
Face Plate
12"
(305mm)
Max.
FP531a
BR/BC
mantel clearances
9/03 djt
"
12"
(305mm)
Max.
12"
(305mm)
Min.
1"
(38mm)
*
12"
(305mm)
Min.
1"
(38mm)
6"
(159mm)
Min.
12"
(305mm)
Max.
12"
(305mm)
Min.
1"
(38mm)
6"
(159mm)
Min.
Mantel Clearance - Radiant Model - No
Noncombustible Facing Material
Combustible
Mantel and
Trim
Finished
Wall
Header
Standoff
Noncombustible
Material
Radiant
Surround
Face
Fireplace Opening
* Minimum width from top of sur-
round to bottom of screen rail
Combustible
Mantel and
Trim
Finished Wall
Header
Standoff
Noncombustible
Material
Radiant
Surround
Face
Fireplace Opening
Mantel Clearance - Radiant
Model - with Noncombustible
Facing Material
Combustible
Mantel and
Trim
Finished Wall
Header
Standoff
Noncombustible
Material
Circulating
Surround
Face
Fireplace Opening
Noncombustible
Facing Material
Mantel Clearance -
Circulating Model
2 x 4 Stud
Finished Wall
Must be sealed with non-
combustible material
Fireplace Front
Top View
FP531a
Fig. 21 Mantel clearances.