Vermont Casting 2478 Electric Heater User Manual


 
14
Dutchwest Non-Catalytic Convection Heater
30002278
Distance from Center of Flue Collar to Wall in Top-Exit Installations
Dutchwest Convection Heater Model 2478
NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col
-
lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the
wall protector.
ST427
dutchwest
flue centerline
6/30/00 djt
A
B
C
E
D
F
C
F
Chimney Connector Side Rear Corner Side Rear Corner
Listed, Approved (A) 30” (B) 13” (C) 18¹⁄₂ (D) 21” (E) 12¹⁄₂ (F) 18”
Double-wall, with (762 mm) (330 mm) (470 mm) (533 mm) (318 mm) (457 mm)
flue collar shield
Single wall, with (A) 27” (B) 13” (C) 18¹⁄₂ (D) 20” (E) 9” (F) 15”
Connector heat shields (686 mm) (330 mm) (470 mm) (508 mm) (229 mm) (381 mm)
and flue collar shield
Single wall with no (A) 33” (B) 23” (C) 26¹⁄₂ (D) 20” (E) 17” (F) 21¹⁄₂
heat shields (838 mm) (584 mm) (673 mm) (508 mm) (432 mm) (546 mm)
UNPROTECTED SURFACES PROTECTED SURFACES
Corner Corner
Parallel Installations Installations Parallel Installations Installations
ST427