Celestron VMC30SB-1 Heat Pump User Manual


 
Installation Manual 23
ENGLISH
Installation
Forming the Piping
Form the piping by wrapping the
connecting portion of the indoor unit
with insulation material and secure it
with two kinds of vinyl tapes.
• If you want to connect an additional drain
hose, the end of the drain outlet should be
routed above the ground. Secure the drain
hose appropriately.
In cases where the outdoor unit is
installed below the indoor unit
perform the following.
1. Tape the piping, drain hose and connecting
cable from down to up.
2. Secure the tapped piping along the exterior
wall using saddle or equivalent.
In cases where the Outdoor unit is
installed above the Indoor unit
perform the following.
1. Tape the piping and connecting cable from
down to up.
2. Secure the taped piping along the exterior
wall. Form a trap to prevent water entering
the room.
3. Fix the piping onto the wall by saddle or
equivalent.
Taping
Drain hose
Pipings
Connecting cable
Trap is required to prevent water
from entering into electrical parts.
Seal small openings
around pipings with a
gum type sealant.
Taping
Seal a small opening
around the pipings
with gum type sealant.
Trap
Trap