THERMIDISTAT CONTROL CONFIGURATION RECORD
Date
Owner/Operator
A) Hardware Configuration
Switch A ____ AC/HP Select. (OFF = AC)
Switch B ____ 1 or 2-Speed Compressor. (OFF = 1-Speed)
Switch C ____ Smart Recovery. (OFF = Enable)
Switch D ____ Installer Test. (OFF = Disable)
Thermidistat Model No.
B) Mode Settings
____ Hold (On or Off)
____ Mode (Off, Heat, Cool, Auto, Eheat)
____ Heating Set Point Value
____ Cooling Set Point Value
____ Fan (Auto or On)
C) Configuration Options
D) Schedule
E) Humidity Settings
Heat Mode Cool Mode
Selection Set Point% Display
Normal Humidify _________ (hu)
Fan Humidify _________ (hu, Fan)
Auto Humidify _________ (hu, AUTO)
Auto and Fan Humidify _________ (hu, AUTO, Fan)
Humidify Off no set point (hu, OF)
1 ______ Anticipator (1-9: factory default = 3)
2 ______ Clean Filter Timer (Off or 1-9: factory default = 2)
3 ______ Fahrenheit or Celsius (F or C: factory default = F)
4 ______ Fan On with W (Off or On: factory default = Off)
5 ______ Variable Speed ICM Motor (Off or On: factory default = Off)
6 ______ Cooling Lockout Below 55°F (Off or On: factory default = Off)
7 ______ Variable Speed Superdehumidify (Off or On: factory default = Off, or Not Available)
8 ______ Auxiliary Heat Lockout Setting (Off or 5-55°F: factory default = Off, or Not Available)
9 ______ Intelligent Heat Staging Selection (Off or On: factory default = Off, or Not Available)
10 ______ Dual Fuel Equipment Selection (Off or On: factory default = Off, or Not Available)
11 ______ Balance Point Setting (Off or 5-55°F: factory default = Off, or Not Available)
12 ______ Defrost Heat Select (0, 1, 2, 3: factory default = 0, or Not Available)
13 ______ Room Temperature Offset (-5 to +5: factory default = 0)
14 ______ Heat/Cool Dead Band (0 to 6: factory default = 2)
15 ______ Enable Auto Mode (On or Off: factory default = On)
16 ______ Enable Super Comfort Heat Mode (Off or On: factory default is Off, or not Available)
17 ______ Enable Non-Programmable Operation (nP or P: factory default is P for programmable)
Mon
Tue
Wed
Thu
Fri
Sat
Sun
TIME HEAT COOL TIME HEAT COOL TIME HEAT COOL TIME HEAT COOL
WAKE DAY EVE SLEEP
A99015
Selection Set Point% Display
Normal Dehumidify _________ (d hu)
Cool to Dehumidify _________ (d hu, COOL)
Dehumidify Off no set point (d hu, OF)
E) Vacation Humidity Settings
Heat Mode Cool Mode
Selection Set Point% Display
Normal Humidify _________ (hu, OUT)
Auto Humidify _________ (hu, OUT,AUTO)
Auto and Fan Humidify _________ (hu, OUT,AUTO, Fan)
Humidify Off no set point (hu, OUT, OF)
Selection Set Point% Display
Normal Dehumidify _________ (d hu, OUT)
Cool to Dehumidify _________ (d hu,OUT,COOL)
Dehumidify Off no set point (d hu, OUT,OF)
✂
Cut and Save for Customer File
Copyright 1999 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 tstt23si
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
Tab misc. misc.
PC 101 Catalog No. 03TS-TA17 Printed in U.S.A. Form TSTAT-23SI Pg 12 8-99 Replaces: TSTAT-19SI