Carrier ZC Air Conditioner User Manual


 
Sealing tape and flashing are not included with
machine.
NOTE
20
Install the sealing tape and the flashing finishing.
The unit is prepared for this condition.
Install the plastic front, fastening it with two screws
(one on each side).
Positioning the cable on the power outlet side
Power cord is 55 in. (1,4 m) long and extends from
bottom of control panel. See Step 24, if power cord
must be relocated to opposite side of unit. Do NOT
use a plug adapter or extension cord.
NOTE
Unit model/catalog number, service/discrete number,
and serial number can be found on the nameplate.
When calling for information and service, be sure
to provide the service/discrete number.
NOTE
ELECTRICAL DATA
1. All wiring must comply with local and national electrical
codes. All wiring must be installed by qualified and
skilled electricians. If you have any questions regarding
the following instructions, contact a qualified electrician.
2. Check available power supply and solve any household
wiring problems BEFORE installing and operating this
unit.
3. An individual branch circuit and single receptacle used
only for this air conditioner, must be available. See Table
1 for suggested wire sizes for individual branch circuit.
4. For your safety and protection, this unit is grounded
through the power cord plug when plugged into a matching
wall outlet. If you are note sure whether your wall
outlet is properly grounded, please consult a
qualified electrician.
5. The wall outlet you select must macth the plug on the
unit power cord, and must be within reach of the installed
unit.
6. Follow fuse specifications indicated on unit
nameplate. See Table 2. Nameplate is located
above unit control panel inside the air discharge
section. For clear access to nameplate, front grille
must be removed as described on page 6.