Carrier 40KMQ------301 Air Conditioner User Manual


 
GB - 7
40KMC------310/ 40KMQ------310
ENGLISH
Room controller wired control
Auto mode setting will be displayed by blinking the fan Medium
speed and High speed icons in order (Med then Hi then repeat).
Low
Medium
High
Automatic
(Fan speed will automatically switch to the
value required for optimum comfort).
When this function is activated, the dotted
symbols will flash.
Louver mode selection
To enter louver mode selection, make sure the Room Controller is
on and hold the
FAN button down for 5 seconds.
After 5 seconds, the selected louver setting will be displayed.
By pressing the up and down buttons the user can modify
the louver desired configuration.
The two settings will be displayed in the following way:
S with Swing Louver Icon - represents Swing Louver.
A with Auto Louver Icon - represents Auto Louver.
Press
FAN button to exit LOUVER Mode Selection.
This mode will exit automatically after 10 seconds if no buttons are
pressed.
The only way to change the operation mode, is to go back to this
menu.
NOTE:
If units are grouped to one Room Controller , all units will end
up having the same louver value.
Louver Mode selection is not available during OFF mode.
:AUTO Automatic louvre positioning to the best position
for the selected operating mode.
:SWING Louvres swing continuously.
FAN ONLY Mode:
ICONS Energized:
Room Temperature if configured for Room Thermistor Override
(operated by Room Controller), otherwise nothing.
FAN/LOUVER Icon with the user selected Fan and Louver
settings.
Buttons available:
•“
MODE and FAN buttons are available.
fan only Ventilation operation only.
UP and DOWN button
(Selecting the desired temperature)
Pressing either the UP or DOWN buttons will modify the desired
temperature.
The maximum desired temperature is 32°C (90°F) and the
minimum desired temperature is 17°C (63°F).
Whenever the setpoint is being displayed, the
SET TEMP icon is
illuminated.
Whenever the display mode is changed from C to F, the setpoint is
set to the default start-up values of 22°C for C mode and 72°F for
F mode.
If the air sensor built in the Room Control is enabled, the
display will indicate the room temperature after few seconds.
FAN button
(Adjusting the ventilation speed)
Pressing the FAN button will cause the fan speed to change.
The
FAN SPEED button must be pressed and then released
to reach the desired speed (Low, Medium, High or Auto).
The icon on the display indicates that change has occurred.
up
down