Carrier 1620 Air Cleaner User Manual


 
4
Step 3 Mount Cabinet
a. Turn off power to the heating and cooling system.
b. Remove the existing fan coilfilter and discard.Excessive
systemstatic pressuremay resultift he InfinitytAirPuri-
fier is used with other filtration devices.
c. Remove the air purifier cartridge and enhancement mod-
ule from the Infinityt Air Purifier cabinet.
d. Position the cabinet between the fan coil and return air
duct (see Fig. 4and 5). Atransition duct may berequired.
NOTE: The fan coil cabinet screws holding the filter rack should
be used to attach the air purifier cabinet.
e. Gasket tape between the fan coil and the air purifier cabi-
net is already factory installed.
f. Mounting holes are provided for fan coil attachment.
g. Use return duct adapters provided to attach return duct-
work (See Fig. 6).
h. Seal seams with tape or caulking after the Infinityt Air
Purifier cabinet has been secured.
ELECTRICAL SHOCK AND HIGH V OLTAGE
HAZARD
Failure to follow this warning could result i n personal
injury or death.
Before installing or servicing system, always turn off main
power to system. There may be more than 1 disconnect
switch.
!
WARNING
UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage.
Cabinets will support a maximum weight of 400 lbs when
installed beneath a vertical fan coil or air--handling unit.
When setting fan coil on cabinet, do not drop it into place.
Position the fan coil correctly on the cabinet to prevent a
corner from slipping down and damaging the cabinet or its
components.
CAUTION
!
Mounting Cabinet Vertical
Mounting Cabinet Horizontal
Return Duct
Adapters (x4)
Return Duct
Adapters (x4)
A06389
A06388
Fig. 5 --- Mounting Infinityt Air Purifier Cabinet for F an Coils
A06392
Fig. 6 --- Use of Return Duct Adapters
GAPAB