Caframo 9206 Electric Heater User Manual


 
Thermostat Switch
This control automatically cycles ON/OFF to
regulate and maintain desired room
temperature. Turn knob clockwise towards
to increase, and counterclockwise
towards to decrease the room temperature.
ANTI-FREEZE SETTING
This feature automatically turns on your heater
when room temperature drops to 38°F (3°C)
and will keep the heater running to maintain
this temperature. Anti-freeze protection only
applies to con ned areas, it will not heat
your entire house. To engage anti-freeze, turn
thermostat to and select an output heat
setting (1-4). The lower settings will use less
power but the heater will remain on longer.
True North Operating Instructions
This model has two-stage overheat protection: a manual reset thermostat and a one time
thermal fuse. If the ow of air becomes blocked, the heater will automatically turn off
when the internal temperature reaches 55°C. The unit will stay off. To reset see point 17.
Care and Maintenance
There are no user serviceable parts in this heater. Do not attempt to service this unit.
Your heater has been designed for many years of problem-free operation. The motor is
permanently lubricated and does not require oiling. However, since this model moves
a high volume of air, it does require periodic cleaning. Unplug the heater and using a
vacuum, clean the air intakes on the top and bottom of the unit as well as the front grill.
PILOT LIGHT
(Illuminated when power is on.)
NOTE: If the pilot light is on but
the heater is not working, turn the
thermostat in a clockwise direction.
o
Heat Selector Switch
HI OUTPUT (1500W, HI Fan)
Maximum heat/ High air circulation
Heat an area quickly.
ENERGY SAVER (900W, HI Fan)
Moderate heat/High air circulation
Maintain room temperature with thermostat.
ENERGY SAVER (900W, LO Fan)
Silent operation/Moderate heat output
Maintain room temperature with thermostat.
SLEEP MODE (600W, LO Fan)
Silent operation/Low heat output
Gentle heat for small areas.
FAN ONLY
OFF (no power to fan or element).
t
A