Bunn H5M Water Heater User Manual


 
5
INITIAL SET-UP
CAUTION - The dispenser must be disconnected from the power source throughout the initial set-up, except
when specified in the instructions.
1. Remove the upper rear panel and rotate the control thermostat
knob fully counterclockwise to the OFF position and replace
the panel.
2. Connect the dispenser to the power source and turn-on the water
supply.
3. Water will automatically flow into the tank to the proper level
and shut-off. This will take approximately 10 minutes.
4. Disconnect the dispenser from the power source, remove the
upper rear panel and place the control thermostat knob fully
clockwise to the ON position, and replace the panel.
5. Connect the dispenser to the power source and wait approxi-
mately twenty minutes for the water in the tank to heat.
6. On models with ready indicator, the indicator will glow when the
proper water temperature for use is achieved.
DRAINING THE DISPENSER
CAUTION - The dispenser must be disconnected from the power source throughout these steps.
1. Disconnect the dispenser from the power source.
2. Shut-off and disconnect the incoming water supply
3. Remove the 4-40 screws at the sides of the top panel.
4. Gently remove one of the grommets from the tank lid.
5. Insert a tube to the bottom of the tank and syphon ALL of the water out. Bunn-O-Matic has a syphon assem-
bly available (#12440.0000) for this purpose.
NOTE - The dispenser must be full using the INITIAL SET-UP steps before reconnecting to the power source.
CLEANING
The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning
all surfaces on Bunn-O-Matic equipment.
WALL MOUNTED INSTALLATION
If the dispenser is wall mounted, the bottom of the dispenser should be at the same height as a counter or
table top. Use B.O.M. part #12542.0000 for side mounted Wall Bracket Kit or # 13125.0001 for front mounted
Wall Bracket Kit .
SUPPORT FOR LARGE RECEPTACLES
CAUTION: If the dispenser is to be used with larger receptacles such as pitchers or pots, those receptacles must
be adequately supported during dispensing of hot water to avoid spillage of very hot water. This support may be
provided by a table or counter top, or use B.O.M. part #12599.0000 Shelf Kit
P1781
10267 071900