6
PROGRAMMING
When power is applied to the dispenser, the display located on the bottom of the main circuit board will show
the software version for 5 seconds, and then it will show the model number (see chart below) it will then go
to (-). While the tank is fi lling, the display will read (FIL). When the tank is full the display will show the model
number and then go to (-).
LEFT
BUTTON
CENTER
BUTTON
RIGHT
BUTTON
39338.1 072409
MODEL DISPLAYS
(H5H) 5 Gallon High Voltage Unit (200-240V)
(H5L) 5 Gallon Low Voltage Unit (100-120V)
(HPC) 5 Gallon Portion Control Unit (all)
(H10) 10X (all)
LEVEL 1 PROGRAMMING
1. Before programming any settings into the Control Board, confi rm the correct model
number is entered.
2. Do this by pressing and holding down on the center button until P1 appears on the
display. Release the center button. The display will now show the model number
(ex: H5H). Now scroll with the
(+/-) buttons
through the models listed above until
the display matches the model you are working with.
3. Press and release the center button once more. The display will show P2. Display
will now show the tank temperature (ex: 200).
Press the (+) button to increase the
temperature set point, or the (-) button to decrease the set point.
NOTE: If the unit is a H5X or H10X, set the Tank Temperature to 212°F.
4. After the Tank Temperature is entered, press and release the center button once
more. The display will read P3, then show the ready temperature set point. Factory
default is 195° F for most dispensers, and 85° F for some.
5. Press the (+) button to increase the set point, or the (-) button to decrease the set
point.
6. To exit Level 1 Program press and release the center button once more. The display
will show Software version, then model number, then (-).
Switch must be in “SET” position for
access into programming modes.