New Buck Corporation MODEL FP-327-ZC Indoor Fireplace User Manual


 
WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE
HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO
AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN IN THE SAME ROOM AS GAS LOGS.
WARNING: CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT
BE PLACED ON OR NEAR THESE GAS LOGS.
WIRING DIAGRAM
NOTE: If any of the original wire as supplied with the gas appliance must be replaced, it must be
replaced with type 16ga., 105
o
C. rating wire or its equivalent.
NOTE: The blower assembly is standard for this appliance, and is installed by the
manufacture.Installation and repair should be done by a qualified service person. This heater
should be inspected before use and at least annually by a qualified service technician. More
frequent cleaning may be required due to excessive lint from carpeting, bedding material,
etc. It is imperative that control compartments and circulating air passageways of the heater
be kept clean.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
MOTOR
RHEOSTAT
THERMOSTAT
GREEN
JUMPER
WHITE
BLACK
BLACK
JUMPER
JUMPER
POWER CORD
Figure 15
Page 30