Page 13
D.
Vertical wall exit using (6" DVL Close Clearance pipe with elbow
and any listed 2100° UL 103 HT. TYPE Chimney
and
Listed 2100° UL HT T-Box assembly
)
With optional close clearance shield and pipe shield
Model FS 21 minimum clearance to combustibles
C
C
C
C
NOTE: All clearances are to combustibles with close clearance shields and pipe shield, DVL
Close Clearance pipe with elbow and minimum floor protector.
Figure 8.
A B C D E F G
MODEL 21 19” 7" 7" 8.5" 8" 6" 16"
DVL CLOSE
CLEARANCE
PIPE
IN
SIDE
WALL
CEILING
Maintain 18"Minimum Clearance
WALL
PASS-THROUGH
CONNECTOR
CENTER LINE
OF ELBOW
MARK PLUMB
LINE ON WALL
LISTED 2100° UL 103 HT TYP.
CHIMNEY REEFER TO
MANUFACTURER’S
INSTALLATION INSTRUCTION
LISTED 2100° UL 103 HT
TYP. CHIMNEY T-BOX
ASSEMBLY REFER TO
MANUFACTURER’S
INSTALLATION
INSTRUCTION
Figure 9.
NOTE:
optional close clearance shield
optional pipe shield.
NOTE:
See Page 22 for
installation of
optional close
clearance shields
and pipe shield
BACK
WALL
A
E
B
F
D
G
A
E
B
D
F
BACK WALL
SIDE WALL
PROTECTOR PAD
G
H