Bryant BW4B Boiler User Manual


 
11
SPECIFICATIONS
UNIT SIZE 042
075 112 150 187 225
SectionsFine Grain Cast-Iron
No.234567
GAS CONTROLS INTERMITTENT PILOT
Gas Valve Honeywell
Inlet Size
In.
1/2 FPT
Pilot Assembly Honeywell
Spark Generator Honeywell
BurnersStainless/Titanium Alloy No. 123456
Burner OrificeDrill Size Natural 32 34 34 34 34 34
CONTROLS
Limit Control Range
°
F 180240
Pressure/Temperature Gage Psig 060
°
F60260
Pressure Relief Valve Setting Psig 30
Circulator RelayAquastat
Honeywell (Factory Installed)
CIRCULATOR
Taco Model 007
Full Load Amps 0.70
Flange Size FPT In. 1-1/4
Model BW3 Gas-Fired Induced-Combustion Water Boilers
are the answer to energy-efficient residential hydronic
heating. They provide fast, almost instant, heat quietly and
economically.
These boilers provide quality design in a small, compact unit
easily installed in a basement, garage, or utility room. They
can be installed on a combustible floor when an optional
combustible floor kit is used.
The design of model BW3N is CSA and A.G.A. certified for
use with natural gas and is convertible to propane gas with
accessory kit.
FEATURES
RANGE OF CAPACITIES
Six sizes ranging from 42,500 through
225,000 Btuh input.
COMPLETELY PACKAGED
Each boiler is completely assembled,
including all controls (except room thermostat). All necessary wiring is
factory installed. The boiler is ready for gas, water, room thermostat,
and electrical power connections as shipped.
VENTING
This boiler can be vented into any approved chimney or
Type B-1 vent. Common-venting with an existing water heater is
acceptable in vertical vent systems. See the Installation Instructions
for common venting requirements. The induced-combustion design
also eliminates the need for a vent damper.
THERMAL-PIN CAST-IRON SECTIONS
These sections speed
heat transfer from the flue gases to the boiler water, with faster ther-
mostat response, providing greater comfort and economy.
TITANIUM COMPOSITE BURNERS
Provide quiet operation,
corrosion resistance, and improved combustion efficiency. Propane
convertible with accessory kit.
CONTROLS
An automatic gas valve and intermittent pilot provide
quiet, dependable operation of the burners. Factory-installed safety
components provide maximum safety against overheating, pressure
buildup, and low-water operation.
INSULATED CASING
Fully insulated with fiberglass for maximum
operating efficiency and economy.
SECTIONS TESTED
Each section is hydrostatically tested to
50 psig. Individual sections are tested to 125 psig at factory.
Assembled sections are tested to 75 psig at the factory. The
maximum allowable pressure is 50 psig for hot water boilers.
UNIT CONVERTIBLE
The Boiler is listed for power venting with field
controls power venting kit.
WARRANTY
The cast-iron sections are covered by a non-prorated
20-year warranty on the entire assembly. Circulator pump covered by
3-year warranty. All other parts are covered by a 1-year limited
warranty.
MODEL BW3