31
Option 14 — Humidity Display Offset Adjust
The percentage to be added to the displayed humidity to calibrate or deliberately
miscalibrate the measured room humidity (--9% to +9% RH).
Default is 0.
Option 15 — Enable Auto Mode
This selection is not available if the Thermidistat Control is configured as Heat
Only or Cool Only in Option 1. This allows the homeowner to select auto
changeover mode in addition to heat and cool. This allows the Thermidistat
Control to automatically change between heating mode and cooling mode when
sufficient demand for heating or cooling exists.
On — Auto mode is available.
OF — Auto mode is not available.
Default is On.
Option 16 — Maximum Cycles Per Hour
This selection limits the number of cycles per hour that the Thermidistat Control
allows the system to operate. Selections are 2, 4, 6.
2 — The heating and cooling outputs will be energized no more than 2 times per
hour. When an output is energized, it will not be energized again for 30 minutes.
4 — The heating and cooling outputs will be energized no more than 4 times per
hour. When an output is energized, it will not be energized again for 15 minutes.
6 — The heating and cooling outputs will be energized no more than 6 times per
hour. When an output is energized, it will not be energized again for 10 minutes.
Default is 4.