Table 4 – Equipment Configuration Outputs
EQUIPMENT
CONFIGURATION
OPTION #1
HARDWARE
CONFIGURATION
COOL
STAGE
1
COOL
STAGE
2
HEAT
STAGE
1
HEAT
STAGE
2
HEAT
STAGE
3
EM
HEAT
STAGE
1
Single--stage AC AC Y/Y2 -- W/W1 -- -- --
Single--stage AC
HP
2S
Y/Y2 -- W/W1
W/W1
O/W2/B
-- --
Single--stage HP
RVS =C
HP
Y/Y2
O/W2/B
-- Y/Y2
Y/Y2
W/W1
-- W/W1
Single--stage HP
RVS =H
HP Y/Y2 --
Y/Y2
O/W2/B
Y/Y2
W/W1
O/W2/B
-- W/W1
Single--stage HP
RVS =C
2S
Y/Y2
O/W2/B
-- Y/Y2
Y/Y2
W/W1
-- W/W1
Single--stage HP
RVS =H
2S Y/Y2 --
Y/Y2
O/W2/B
Y/Y2
W/W1
O/W2/B
-- W/W1
Two--stage AC 2S Y1
Y/Y2
Y1
W/W1
W/W1
O/W2/B
-- --
Two--stage HP
RVS =C
2S
Y1
O/W2/B
Y1
Y/Y2
O/W2/B
Y1
Y1
Y/Y2
Y1
Y/Y2
W/W1
W/W1
Two--stage HP
RVS =H
2S Y1
Y1
Y/Y2
Y1
O/W2/B
Y1
Y/Y2
O/W2/B
Y1
Y/Y2
O/W2/B
W/W1
W/W1
Single--stage
Hybrid Heat
RVS =C
2S
Y/Y2
O/W2/B
-- Y/Y2 W/W1 -- W/W1
Single--stage
Hybrid Heat
RVS =H
2S Y/Y2 --
Y/Y2
O/W2/B
W/W1 -- W/W1