Bryant 583B Gas Heater User Manual


 
NOTE: Read
the entire
instruction manual
before starting the
installation.
TABLE OF CONTENTS
SAFETY CONSIDERATIONS.....................................................1
INTRODUCTION..........................................................................2
RECEIVING AND INSTALLATION ..........................................2
ICM FIOP PRE-START-UP..........................................................2
Electrical Connections ..............................................................2
Control
Voltage Connections..............................................2
Standard
Connection............................................................2
Easy Select™—583B
..........................................................2
583B Sequence of Operation ..............................................4
Easy Select™—683B
..........................................................5
683B
Sequence of Operation ..............................................7
Easy Select™—702B & 602B............................................7
702B & 602B Sequence Of Operation...............................9
ICM FIOP START-UP................................................................10
583B Start-Up (ICM FIOP)....................................................10
683B Start-Up (ICM FIOP)....................................................10
702B:
Start-Up (ICM
FIOP) ..................................................11
602B:
Start-Up (ICM FIOP) ..................................................11
ELECTRICAL DATA & SCHEMATICS—ICM FIOP.............12
Physical Data & Electrical Schematics..................................12
Tables For
System Set-Up......................................................12
CARE AND MAINTENANCE...................................................12
TROUBLESHOOTING ...............................................................13
START-UP CHECKLIST............................................................13
NOTE TO INSTALLER READ THESE INSTRUCTIONS
CAREFULLY AND COMPLETELY before installing this unit.
Also, make
sure the Owner’s Manual and Service Instructions are
left with the unit after installation.
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can be
hazardous due to system pressure and electrical components. Only
trained and qualified personnel should install, repair, or service
air-conditioning equipment.
Untrained personnel can perform basic maintenance functions of
cleaning coils and filters. All other operations should be performed
by trained service personnel. When working on air-conditioning
equipment, observe precautions in the
literature, tags, and labels
attached to the unit, and other safety precautions that may apply.
Follow all safety codes. Wear safety glasses and work gloves. Use
quenching cloth for unbrazing operations. Have fire extinguisher
available for all brazing operations.
WARNING: Improper installation, adjustment, alter-
ation, service, maintenance, or use can cause explosion,
fire, electric shock, or other occurrences, which could
cause serious injury
or death or
damage your
property.
Consult a qualified installer or service agency for infor-
mation or assistance. The qualified installer or agency
must use only factory-authorized kits or accessories when
modifying this product.
Recognize safety information. This is the safety-alert symbol .
When you see this symbol on the product or in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, CAU-
TION, and NOTE. Danger identifies the most serious hazards,
which will result in severe personal injury or death. Warning
indicates a condition that could cause serious personal injury or
death. Caution is used to
identify unsafe practices, which
would
result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in
enhanced installation, reliability, or operation.
The power supply (volts, phase, and hertz) must correspond to that
specified on unit rating plate.
The electrical supply provided by the utility must be sufficient to
handle load imposed by this unit. Electrical supply must match the
voltage requirements listed on unit rating plate.
This installation must conform with local building codes and with
NEC (National Electrical Code). Refer to provincial and local
plumbing or waste water codes and other applicable local codes.
Approved for outdoor installation on wood flooring or on class A,
B or C roof covering materials.
Fig. 1—Puron® Unit (583B Shown)
C99087
ICM FIOP
INSTALLATION INSTRUCTIONS
installation, start-up,
—1—
and operating instructions
583B
683B
602B
702B
Cancels:II583B-24-2II583B-24-3
11-01