SPECIFICATIONS
* Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft above sea level. Refer to
National Fuel Gas Code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level.
Capacity and AFUE in accordance with U.S. government DOE test procedures.
‡•Airflow shown is for bottom only return-air supply with factory-supplied 1-in. washable filter(s).
For air delivery above 1800 CFM, see Air Delivery table for other options.
An airflow reduction of up to 7% may occur when using the factory-specified 4-5/16-inch wide, high efficiency media filter.
For best furnace efficiency when using the 4-5/16-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range.
** Time-delay type is recommended.
ICSIsolated Combustion System
N/ANot Applicable
UNIT SIZE 036111 048111 060111 048135 060135 060155
RATINGS AND PERFORMANCE
Input Btuh* 110,000 110,000 110,000 132,000 132,000 154,000
Capacity (Btuh) Nonweatherized ICS 89,000 89,000 89,000 107,000 107,000 124,000
AFUE Nonweatherized ICS 80.0 80.0 80.0 80.0 80.0 80.0
Certified Temperature Rise Range °F5585 4575 2555 5080 4070 5080
Certified External Static Pressure Heat/Cool 0.20/0.50 0.20/0.50 0.20/0.50 0.20/0.50 0.20/0.50 0.20/0.50
Airflow CFM Heating 1175 1415 1750 1645 1775 1770
Cooling 1205 1575 2225 1620 2025 2055
ELECTRICAL
Unit VoltsHertzPhase 115601
Operating Voltage Range MinMax 104127
Maximum Unit Amps 8.0 10.1 14.4 10.1 13.3 14.0
Maximum Wire Length (Measured 1 Way in Ft) 35 28 31 28 33 31
Minimum Wire Size 14 14 12 14 12 12
Maximum Fuse or Ckt Bkr Size (Amps)** 15 15 20 15 20 20
Transformer (24v) 40va
External Control Heating 12va
Power Available Cooling 35va
Air Conditioning Blower Relay Standard
CONTROLS
Limit Control SPST
Heating Blower Control Solid-State Time Operation
Burners (Monoport) 5 5 5 6 6 7
Gas Connection Size 1/2-in. NPT
GAS CONTROLS
Gas Valve (Redundant) White Rodgers
Min Inlet Pressure (In. wc) 4.5 (Natural Gas)
Max Inlet Pressure (In. wc) 13.6 (Natural Gas)
Ignition Device Hot Surface
BLOWER DATA
Direct-Drive Motor HP (PSC) 1/3 1/2 3/4 1/2 3/4 3/4
Motor Full Load Amps 5.8 7.9 11.1 7.9 11.1 11.1
RPM (Nominal)Speeds 10754 10754 10754 10754 10754 10754
Blower Wheel Diameter x Width (In.) 10 x 7 10 x 8 11 x 10 10 x 8 11 x 10 11 x 10
Filter Size (In.)Permanent Washable (1) 16 x 25 x 1 (1) 20 x 25 x 1 (1) 24 x 25 x 1 (1) 20 x 25 x 1 (1) 24 x 25 x 1
FACTORY-AUTHORIZED DEALER-INSTALLED ACCESSORIES
Twinning Kit N/A KGATW0401HSI
Gas Conversion Kit(Natural-to-Propane) KGANP2001ALL
Gas Conversion Kit(Propane-to-Natural) KGAPN1601ALL
Air Cleaner Model AIRA or 902B
Humidifier Model HUM
Ventilator Model VA3B, VB5B, VC5B, or VL3A