DETAI LED COOLING CAPACITIES# CONTINUED
EVAPORATOR AIR
CONDENSER ENTERING AIR TEMPERATURES °F (°C)
75 (23.9) 85 (29.4) 95(35) 105(40.6) 115(46.1) 125 (51.7)
CFM
EWB
°F(°C)
CapacityMBtuh
Total
Sys.
KW**
CapacityMBtuh
Total
Sys.
KW**
CapacityMBtuh
Total
Sys.
KW**
CapacityMBtuh
Total
Sys.
KW**
CapacityMBtuh
Total
Sys.
KW**
CapacityMBtuh
Total
Sys.
KW**
Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
165ANA060---B Outdoor Section With CAP**6024A** Indoor Section
1700
72 (22.2) 71.24 37.12 4.00 68.02 35.88 4.40 64.60 34.58 4.85 60.97 33.21 5.34 57.00 31.74 5.88 52.58 30.13 6.45
67 (19.4) 65.05 45.36 3.93 62.11 44.11 4.34 59.00 42.80 4.79 55.69 41.42 5.28 52.10 39.96 5.81 48.14 38.37 6.39
62 (16.7) 59.46 53.54 3.88 56.82 52.28 4.29 54.05 50.95 4.73 51.13 49.53 5.23 48.05 47.98 5.76 45.09 45.09 6.35
57 (13.9) 57.44 57.44 3.86 55.34 55.34 4.27 53.10 53.10 4.72 50.70 50.70 5.22 48.06 48.06 5.76 45.10 45.10 6.35
1900
72 (22.2) 72.35 38.59 4.08 68.99 37.32 4.49 65.44 35.99 4.94 61.66 34.60 5.43 57.56 33.11 5.96 53.00 31.48 6.53
67 (19.4) 66.10 47.70 4.02 63.03 46.42 4.43 59.80 45.09 4.87 56.37 43.70 5.36 52.66 42.22 5.90 48.57 40.59 6.47
62 (16.7) 60.59 56.75 3.97 57.87 55.43 4.37 55.06 54.00 4.82 52.25 52.25 5.31 49.45 49.45 5.86 46.30 46.30 6.44
57 (13.9) 59.43 59.43 3.95 57.19 57.19 4.36 54.82 54.82 4.82 52.26 52.26 5.32 49.46 49.46 5.86 46.30 46.30 6.44
2100
72 (22.2) 73.20 39.97 4.17 69.73 38.68 4.57 66.07 37.34 5.02 62.19 35.93 5.51 57.98 34.42 6.04 53.29 32.77 6.61
67 (19.4) 66.90 49.94 4.10 63.74 48.64 4.51 60.40 47.30 4.95 56.88 45.89 5.45 53.08 44.38 5.98 48.90 42.71 6.55
62 (16.7) 61.58 59.74 4.05 58.87 58.28 4.46 56.26 56.26 4.91 53.56 53.56 5.41 50.61 50.61 5.95 47.28 47.28 6.53
57 (13.9) 61.12 61.12 4.05 58.77 58.77 4.46 56.26 56.26 4.91 53.57 53.57 5.41 50.61 50.61 5.95 47.28 47.28 6.53
COOLING
INDOOR MODEL
CAPACITY POWER FURNACE MODEL
*CAP**6024A** 1.00 1.00
CAP**6021A** 1.00 1.00
CNPH*6024A** 1.00 1.00
CNPV*6024A** 1.00 1.00
CSPH*6012A** 1.00 1.00
FB4BNB070 1.01 1.02
FE4ANB006 1.01 0.96
FV4BNB006 1.01 0.96
FX4BNB060 1.01 1.02
FX4CN(B,F)060 1.00 0.95
FY4ANB060 1.01 1.02
CAP**6021A** 1.00 0.99 315(A,J)AV060110
CAP**6024A** 1.00 0.99 315(A,J)AV060110
CNPH*6024A** 1.00 0.99 315(A,J)AV060110
CNPV*6024A** 1.00 0.99 315(A,J)AV060110
CNPV*6024A** 0.99 0.98 315(A,J)AV060110
COOLING
INDOOR MODEL
CAPACITY POWER FURNACE MODEL
CSPH*6012A** 1.00 0.99 315(A,J)AV060110
CAP**6021A** 1.00 0.97 315(A,J)AV066135
CAP**6024A** 1.00 0.99 315(A,J)AV066135
CNPH*6024A** 1.00 0.99 315(A,J)AV066135
CNPV*6024A** 1.00 0.99 315(A,J)AV066135
CSPH*6012A** 1.00 0.97 315(A,J)AV066135
CAP**6021A** 1.00 0.97 315(A,J)AV066155
CNPH*6024A** 1.00 0.97 315(A,J)AV066155
CNPV*6024A** 1.00 0.97 315(A,J)AV066155
CSPH*6012A** 1.00 0.97 315(A,J)AV066155
CNPH*6024A** 0.97 0.99 353AAV048080
CSPH*6012A** 0.98 1.00 353AAV048080
CAP**6021A** 0.98 0.97 353AAV060100
CNPH*6024A** 0.98 0.97 353AAV060100
CSPH*6012A** 0.99 0.98 353AAV060100
CAP**6024A** 0.99 0.98 353AAV060120
COOLING
INDOOR MODEL
CAPACITY POWER FURNACE MODEL
CNPH*6024A** 0.99 0.98 353AAV060120
CNPV*6024A** 0.99 0.98 353AAV060120
CSPH*6012A** 0.99 0.98 353AAV060120
CSPH*6012A** 1.00 1.00 355AAV060120
CAP**6021A** 0.98 0.97 313*AV048090
CNPH*6024A** 0.99 0.98 313*AV048090
CSPH*6012A** 0.99 0.98 313*AV048090
CAP**6021A** 0.99 0.96 313*AV060110
CNPH*6024A** 1.00 0.99 313*AV060110
CSPH*6012A** 1.00 0.97 313*AV060110
CAP**6024A** 0.99 0.98 313*AV060135
CNPH*6024A** 0.99 0.98 313*AV060135
CNPV*6024A** 0.99 0.98 313*AV060135
CSPH*6012A** 0.99 0.98 313*AV060135
CNPV*6024A** 0.98 1.01 368RAN060120
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F(27_C) entering air at the indoor coil. For sensible capacities at other than 80_F(27_C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F(27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F(27_ C).
# Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240---94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may
occur.
** System kw is total of indoor and outdoor unit kilowatts.
EWB — Entering Wet Bulb
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
165A