13. CONNECT WIRING (ALL BLOWERS)
Connect cable into wiring box using provided wire connectors.
Connect wires as follow: BLACK to BLACK, WHITE to WHITE and
GREEN or BARE wire under ground screw. DO NOT FORGET TO
CONNECT THE GROUND. Reinstall wiring cover.
WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power from being switched on accidentally.
!
1
HD0007
1) Ground screw
INTERIOR BLOWER: Remove the cable knock-out on the top of the rough-in plate. Remove rough-in plate wiring
cover. Place the wire clamp in the knock-out hole, insert the cable through the wire clamp in the rough-in plate wiring
box. Tighten the wire clamp to secure the cable.
Position insert below the installed custom hood. Pull cable through hole in top of insert.
IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included
with in-line or exterior blower).
14. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS)
INTERIOR BLOWER: Carefully install the rough-in plate
inside the top of the insert with four
(4) lock nuts. See picture beside.
IN-LINE OR EXTERIOR BLOWER: Refer to instructions included with rough-in kit. Secure the rough-in plate inside the
top of the insert with (4) lock nuts.
HD0042
15. INSTALL THE TRANSITION (INTERIOR BLOWER)
Slide the transition over the adapter/damper. Seal the transition to the
adapter/damper by using duct tape.
HD0091