BRK electronic SC7010B Smoke Alarm User Manual


 
brkelectronics.com
ARCHITECTURAL AND ENGINEERING SPEC
INSTALLATION OF ALARM
The combination smoke and carbon monoxide alarm shall be a BRK Model SC7010B
and shall provide at a minimum the following features and functions:
1. A photoelectric smoke sensing chamber and an electrochemical CO sensor.
2. Powered by 120V AC, 60Hz and have a monitored battery backup and a solid
state piezo horn rated at 85dB at 10 ft. and shall be capable of self restoring.The
horn shall have a lower and varying horn frequency to to make it easier for the
elderly with normal age related hearing loss to better hear the horn.
3. The unit shall have an "End of Life" signal. This signal should be capable of
temporarily being silenced for up to 2 days. After about 2 days, the signal will
resume. After about 2-3 weeks the signal cannot be silenced.
4. A visual power-on indicator to confirm unit is receiving AC power or has switched
to battery backup mode. Separate LED 's to indicate a smoke or CO alarm.
5. The CO sensor is adjusted not to detect CO levels below 30 PPM and will not
alarm when exposed to constant levels of 30 PPM for 30 days. It will alarm
at the following levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO
between 10 and 50 minutes and 70 PPM CO between 60 and 240 minutes.
6. Two Latching features: Alarm Latch to easily identify initiating alarm after alarm
condition has subsided. Low battery latch: to visually identify which unit is in low
battery condition. Two Silence Features: Alarm Silence to temporarily silence
nuisance alarms. Low Battery Silence to silence low battery chirp for up to 8 hours.
7. Two Locking features - tamper resistant locking pins that lock battery drawer
and/or alarm to mounting bracket.
8. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and
relative humidity between 10% and 95%.
9. The unit shall have a plug in connector and be capable of interconnection of up to
18 alarms, 12 of which can be smoke alarms.
10. The unit shall at a minimum meet the requirements of UL217 and UL2034,
CSFM, NFPA 72 and 720 and the ICC.
SHIPPING SPECS:
TECHNICAL SPECS
Individual Carton Dimensions 5.13"L x 2.38"W x 5.13"H
Weight 0.74 lbs.
Cube 0.04 ft3
UPC 0 29054 02280 6
Master Carton Dimensions 10.75"L x 7.88"W x 11.06"H
Master Pack 12
Weight 9.4 lbs.
Cube: 0.54 ft3
I2of5: 100 29054 02280 3
Pallet Information
Cases per Layer 22
Number of Layers: 4
Cases per Pallet: 88
Units per pallet: 1,056
Cube: 54.0 ft3
Weight: 892 lbs.
Alarm Dimensions: 5.0” dia x 2.0”H
Weight: 9.3 oz
Operating Voltage: 120V AC 60Hz with two 1.5V AA battery backup
Operating Current: .05 amps (standby/alarm)
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Voice Output: Choice of 11 pre-programmed locations warns of smoke
or CO danger and location of danger
Test/Silence: Electronically simulates smoke or carbon monoxide
condition, causing the unit to alarm
Press and hold test/silence button
Alarm Reset: Automatic when smoke and/or CO clears
Interconnections: Up to 18 units of First Alert or BRK Smoke, CO and
Heat Alarms. Maximum of 12 smoke alarms. See
user’s manual for details.
Smoke Sensor: Photoelectric
CO Sensor: Electrochemical
Indicator Lights/Sounds:
AC Power: Constant Green LED
DC Power: Intermittent Green LED
Local Alarm: Red LED flashes
Remote Alarm: Red LED off
Alarm Latch: Red LED flashes every 5 seconds after local alarm stops
Low Battery Latch: “Power” LED flashes green on for 2 seconds,
off for 2 seconds.
Listing: Listed to UL217 and UL2034 Standards
©2010 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM3077
CAT.
SC7010B
Installation of this smoke alarm must conform to all local electrical
codes and Article 760 of the National Electrical Code (NFPA 70)
and NFPA 72. Interconnected units must meet the following
requirements: wire to be #18 gauge or larger and be rated at least
300V. It is recommended that all units be on the same fuse or
circuit breaker. If local codes do not permit, be sure the neutral
wire is common to both phases.
BATTERY DRAWER LOCK
Remove Pin from
Mounting Bracket
Close Door. Insert Pin in Holes
through alarm and Battery Drawer
5.0"
TOP VIEW SIDE VIEW
MOUNTING
BRACKET
2.0"
THE PARTS OF THIS SMOKE ALARM
A. Unswitched 120VAC 60 Hz source
B. To additional units; Maximum = 18 total
(Maximum 12 Smoke Alarms)
1. Smoke Alarm 5. Junction Box
2. Ceiling or Wall 6. Neutral Wire (White)
3. Power Connector 7. Interconnect Wire (Orange)
4. Wire Nut 8. Hot Wire (Black)
1. Mounting bracket
2. Mounting Slots
3. Locking Pins
4. Hot (Black) AC Wire
5. Nuetral (White) AC Wire
6. Interconnect (Orange) Wire
7. Pull-out Battery Drawer
8. Quick-Connect Plug
2
8
1
7
6
5
4
3
2
678
43 1
5 2
A
B
}
}
43 15