BRK electronic FG225B Smoke Alarm User Manual


 
Individual Carton Dimensions
4.38 ”L x 1.75”W x 4.38”H
Weight
.67lbs.
Cube .02 ft3
UPC FG225B: 0 29054 00303 4
FG250B: 0 29054 00300 3
FG250AB: 0 29054 00311 9
FG250LB: 0 29054 00310 2
Master Carton Dimensions 9.2 ”L x 5.5”W x 5.1”H
Master Pack 6
Weight
3.2 lbs.
Cube .15 ft3
I2 of 5 FG225B: 600 29054 00303 6
FG250B: 600 29054 00300 5
FG250AB: 600 29054 00311 1
FG250LB: 600 29054 00310 4
Pallet Information
Cases per Layer 36
Number of Layers 9
Cases per Pallet 324
Units per Pallet 1,944
Cube 55.0 ft3
Weight 1,107lbs.
Alarm Dimensions: 4.25” dia x 1.6”H
Weight: 4.8 oz.
Operating Voltage: 9V Battery Powered
Temperature Range: 40˚F (4˚C) to 100˚F (38˚C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence:
(FG250)
Electronically simulates smoke condition, causing
the unit to alarm
Alarm Reset: Automatic when smoke clears
Smoke Sensor: Dual Ionization
Indicator Lights:
DC Power: Intermittent Red Light
Listing ETL to UL217 Standard
brkelectronics.com
INSTALLATION OF ALARM
SHIPPING SPECS:
TECHNICAL SPECS:
CAT.
FG225B/FG250B
©2008 BRK Brands, Inc. a Jarden Corporation
company (NYSE: JAH)
3901 Liberty Street Road
Aurora IL 60504-8122
All rights reserved
BRK is a registered trademark of BRK
Brands,Inc.
CM2885
ARCHITECTURAL AND ENGINEERING SPEC
1. A dual ionization sensing chamber.
2. The unit shall be capable of self restoring.
3. A fully screened sensing chamber to resist entry of small insects
thereby reducing the probability of unwanted alarms.
4. Powered by a supervised 9V battery and a solid state piezo horn
rated at 85dB at 10 ft.
5. A visual LED power-on indicator to confirm unit is receiving power or
is in alarm.
6. A full function test button. The test button should check all alarm
functions by stimulating the chamber to simulate a smoke condition,
causing the unit to alarm. Model FG250 also has a silence feature to silence
unwanted nuisance alarms.
7. A tamper resistant locking pin that locks alarm cover to prevent removal
of battery.
8. The unit shall be capable of operating between 40°F (4°C) and
100°F (38°C) and relative humidity between 10% and 90%.
9. The unit shall contain mounting hardware and shall be listed for wall
or ceiling mounting.
10. The unit shall at a minimum meet the requirements of UL217, CSFM,
NFPA 72, NFPA 101, ICC.
11. The unit shall be suitable for use in Recreational Vehicles.
Installation of this smoke alarm must conform to NFPA 72. Always check
your local building codes. Follow all instructions for placement as outlined
in the user’s manual in sections titled “Recommended Locations for
Smoke Alarms” and “Locations to Avoid for Smoke Alarms”.
4.25”
FRONT
VIEW
SIDE
VIEW
Back
View
1.6”
1
2
3
4
5
7
6
8
1. “Open Here”
2. “No Battery” tab
3. Test button or
Test/Silence button (FG250 only)
4. Smoke alarm base
5. Mounting slots
6. Install 9V battery here
7. Locking pin slot
8. Locking pin: Remove and insert in 7
The parts of this smoke alarm
7